Chapter 4: F2000 Customer Replaceable Units (CRUs)
Chassis Replacement
Figure 87 Port 4 Canister-to-
Canister Connection
94
Item
1
Bottom canister PCIe slot locations.
2
Top canister PCIe slot locations.
3 If the system contains 32 Gb FC cards, connect the FC cables to the
FC ports in PCIe slot 1 and PCIe slot 3 on the top canister and the
bottom canister (see
4 Connect one end of the short CAT6A Ethernet cable to Port 4 on the
top canister and the other side to port 4 on the bottom canister (see
Figure
87).
Note: This cable connection is for canister-to-canister
communication and must be in place before applying
power to the system.
Item
1
Port 4 on the bottom canister
2
Port 4 on the top canister
5 Connect one power cable to PSU A and the other cable to PSU B (see
Figure 88
on page 95).
Description
Figure 86
on page 93).
Description