Chapter 4: F2000 Customer Replaceable Units (CRUs)
SSD Assembly Replacement
Figure 187 F2000 Front View
with Drive Slot Numbering
Figure 188 LED Location on an
SSD Assembly (Drive in Slot 07
Shown)
174
In the example RAS ticket, the Event Summary indicates that drive 07
is degraded. A failed drive 07 corresponds to an SSD located in slot 7 at
the front of the F2000 array.
Drive slots are accessible on the front of the F2000 and are numbered
1 through 24 going from left to right (see
A degraded SSD displays either a solid or blinking illuminated amber
LED (see
Figure
188).
Item
LED
1
Drive Fault LED
2
Drive Link/Active
Figure
187).
Action
Amber (solid or blinking): Degraded
drive reported. Replace the drive.
• Off: No drive present
• Green: Drive present
• Green (Blinking): Drive active
Quantum F2000 User's Guide