Configuring the Input and Output for an IP Camera

MAXPRO NVR 5.6 Installation and Configuration Guide
Note:
The Help that opens lists only a few manufacturers. Most cameras are RTSP, and
all RTSP third party cameras can be configured. If the RTSP URL format for a
particular camera type is not listed in the Help, then the URL format can be
obtained from the camera manufacturer.
Click Get Configuration to get the resolution and compression format for the
camera.
For RTSP, all settings such as FPS must be configured on the camera web
page, and the default port 554 must be used.
If "Get Configuration" fails, a message appears to choose the compression
and resolution. You must go to the Camera web page and set both of them,
and then configure the same settings in MAXPRO NVR.
9.
Click Save.
Tip: If a particular camera is not discovered by the system, you can add it manually by clicking
Manual Add.
Most IP cameras have a monitor input and a control output that can be configured. For
example the input of the camera could be connected to a motion detector and the output of
the camera to a door opener. Once configured, movement detected at the door would trigger
the door to be opened. For electrical characteristics of the input and output refer to the
camera documentation.
In MAXPRO NVR, the inputs and outputs of a camera are configured by default in the
database while adding a camera if the integration supports it (Refer to compatibility list on
HOTA for the models with support for IO with MAXPRO NVR and the no of IOs supported by
each model). MAXPRO NVR has a specialized interface that lists the inputs and outputs
associated to the configured cameras.
To configure input and output
1.
Click the Configurator tab. The System page
2.
Click the I/O tab.
C O N F I G U R I N G M A X P R O N V R
Configuring the Cameras
(Figure
6-22) displays by default.