2.7 Program operation mode
Handling
Replacement of system routine
MD 11610 MN_ASUB_EDITABLE controls which of the system routines are to be replaced
by user-defined routines.
Value
0
1
2
Fig. 2-14
The following diagram illustrates which routines are used:
2-112
Meaning
The user-defined routine stored in _N_ASUP_SPF in directory _N_CUS_DIR
is not activated for either RET or REPOS.
The user-defined routine is activated for RET,
the routine provided in the system is activated for REPOS.
The user-defined routine is activated for REPOS,
the routine provided in the system is activated for RET.
User SW
_N_ASUP_SPF
User
RET
Replacing system ASUBs with user routines
ASUP_EDITABLE
0
1
User
REPOS
2
Value stored in MD 11610
Mode Group, Channel, Program Operation, Reset Response (K1)
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
NCK system SW
System
System
ASUB
ASUB
RET
REPOS
System
ASUB
REPOS
System
ASUB
RET