2.7 Structure and functions of the basic program
Relevant parameters (FB1)
MCP
MCPNum = 1 or 2 (number of MCPs)
MCP1In
MCP1Out
MCP1StatSend (n.r.)
MCP1StatRec (n.r.)
MCP1BusAdr
MCP1Timeout (n.r.)
MCP1Cycl (n.r.)
MCPMPI = FALSE
MCP1Stop (n.r.)
MCPBusType = 3
MCP failure switches the PLC to the STOP state. If this is undesirable, OB 82, OB 86 can be
used to avoid a stop. The MCP (as PROFIBUS slave) can also be switched on and off via
SFC12.
In the event of a failure, alarm messages are not generated by the basic program.
M to N is not possible with the MCP variant.
2-70
MCP2In
MCP2Out
MCP2StatSend (n.r.)
MCP2StatRec (n.r.)
MCP2BusAdr
MCP2Timeout (n.r.)
MCP2Cycl (n.r.)
MCP2Stop (n.r.)
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
HHU
HHU = 2 (via COM module)
BHGIn
BHGOut
BHGStatSend
BHGStatRec
BHGInLen
BHGOutLen
BHGTimeout
BHGCycl
BHGRecGDNo
BHGRecGBZNo
BHGRecObjNo
BHGSendGDNo
BHGSendGBZNo
BHGSendObjNo
BHGMPI = FALSE
BHGStop