Detailed description
2.12 Block descriptions
Signal
MMCToIF
HWheelMMC
MsgUser
UserIR
IRAuxfuT
IRAuxfuH
IRAuxfuE
UserVersion
MaxBAG
MaxChan
MaxAxis
ActivChan
ActivAxis
UDInt
UDHex
UDReal
To ensure BP monitoring of the MCP(s), the addresses must be specified as set in SDB 210 on the
1)
810D. The start address is set via SDB 210 on the 810D. In the supplied SDB 210, the start address
is specified as IB 0 for input signals and QB 0 for output signals. If a different start address is
required, this must be specified using the STEP 7 Communication Configuration package.
To ensure BP monitoring of the HHU(s), the addresses must be specified as set in SDB 210 on the
2)
810D.
2-102
I/O
Type
Value range
I
Bool
I
Bool
I
Int
0...25
I
Bool
I
Bool
I
Bool
I
Bool
I
Pointer
Q
INT
1..10
Q
INT
1..10
Q
INT
1..31
Q
ARRAY
[1..10] OF
BOOL
Q
ARRAY
[1.0.31] OF
BOOL
Q
Int
Q
Int
Q
Int
Remarks
Transmission of MMC signals
to interface (modes,
program control, etc.)
true: active
True: Handwheel selection via
MMC
False: Handwheel selection using
user prog.
Number of user areas for messages
(DB 2)
Local data expansion OB40
required for processing of signals
from user
Evaluate T function in OB40
Evaluate H function in OB40
Evaluate DL function in OB40
Pointer to string variable.
The associated string variable is
indicated in the version display
(max. 54 characters).
Number of mode groups
Number of channels
Number of axes
Bit string for active channels
Bit string for active axes
Quantity of integer machine data in
DB20
Quantity of hexadecimal machine
data in DB20
Quantity of real machine data in
DB20
Power Line Basic PLC Program (P3)