Siemens SINUMERIK 840Di Function Manual page 384

Basic machine
Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

Detailed Description
2.1 Velocities, traversing ranges, accuracies
⇒ The scaling factor is calculated using the following formula:
Index 2 defines the "Linear velocity" in the "Scaling factors of physical quantities" list.
Example 2:
In addition to the change in example 1, the machine data input/output of linear accelerations
is to be performed in ft/s
(The internal unit is mm/s
Index 4 defines the "Linear acceleration" in the "Scaling factors of physical quantities" list.
2-10
The scaling factor for the linear velocities is to differ from the standard setting. In this case, bit
number 2 must be set in machine data:
MD10220 $MN_SCALING_USER_DEF_MASK.
MD10220 $MN_SCALING_USER_DEF_MASK = 'H4'; (bit no. 2 as hex value)
, instead of m/s
2
)
2
(initial state).
2
Velocities, Setpoint/Actual-Value Systems, Closed-Loop Control (G2)
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0