Detailed description
2.12 Block descriptions
Description of formal parameters
The table below lists all formal parameters of the M:N function.
Formal parameters of M:N function
Signal
Ack
OPMixedMode
ActivEnable
MCPEnable
Alarm1
Alarm2
Alarm3
Alarm4
Alarm5
Alarm6
Report
ErrorMMC
Note
The block must be called by the user program. The user must provide an instance DB with
any number for this purpose. The call is not multi instance capable.
2-154
I/O
Type
Remarks
I
BOOL
Acknowledge alarms
I
BOOL
Mixed mode deactivated for OP without M to N capability
I
BOOL
Function is not supported. Control panel switchover
Interlocking via MMCx_SHIFT_LOCK in DB 19
I
BOOL
Activate MCP switchover
TRUE = MCP is switched over with operator panel front.
FALSE: = MCP is not switched over with operator panel
front. This can be used to permanently link an MCP. See also
MMCx_MCP_SHIFT_LOCK in DB 19
Q
BOOL
Alarm: Error in MMC bus address, bus type!
Q
BOOL
Alarm: No confirmation MMC1 offline!
Q
BOOL
Alarm: MMC1 is not going offline!
Q
BOOL
Alarm: No confirmation MMC2 offline!
Q
BOOL
Alarm: MMC2 is not going offline!
Q
BOOL
Alarm: Queuing MMC is not going online!
Q
BOOL
Message: Sign of life monitoring MMC
Q
BOOL
Error detection MMC
Power Line Basic PLC Program (P3)