Config Ethernet_Oam Ports (Link Monitor Error Frame Seconds) - D-Link DGS-1100-06/ME Cli Reference Manual

Metro ethernet managed switch
Hide thumbs Also See for DGS-1100-06/ME:
Table of Contents

Advertisement

config ethernet_oam ports (link monitor error frame seconds)

Purpose
Syntax
Description
Parameters
Restrictions
Example usage:
To configure the error frame seconds threshold to 2 and period to 10000 ms for port 1:
DGS-1100-06/ME:5# config ethernet_oam ports 1 link_monitor error_frame
threshold 2 window 10000 notify_state enable
Command: config ethernet_oam ports 1 link_monitor error_frame threshold 2
window 10000 notify_state enable
Success!
DGS-1100-06/ME:5#
DGS-1100-06/ME Metro Ethernet Managed Switch CLI Reference Guide
Used to configure Ethernet OAM link monitoring error frame seconds
configuration for ports.
config ethernet_oam ports [all | <portlist>] link_monitor
error_frame_seconds {threshold < integer 1-4294967295> |
window < integer 1000-60000> | notify_state [ enable | disable]}
The config ethernet_oam ports command is used to configure
Ethernet OAM link monitoring error frame seconds for ports. An error
frame second is one second interval wherein at least one frame
error was detected.
Link monitoring function provides a mechanism to detect and
indicate link faults under a variety of conditions. OAM monitors the
counts of the number of frame errors as well as the number of
coding symbol errors. When the number of error frame seconds is
equal to or greater than the specified threshold in a period and the
event notification state is enabled, it generates an error frame
seconds summary event to notify the remote OAM peer.
[all | <portlist>] – Specifies a range of ports or all ports to be
configured.
threshold <integer 1-4294967295> – Specify the number of error
frame seconds in the period that must be equal to or greater than in
order for the event to be generated. The default value is 1 frame
error.
window <integer 1000-60000> –Specify the period of error frame
seconds summary event. The range is 1000ms-60000ms and the
default value is 60000 ms.
notify_state [enable | disable] – Specify to enable or disable event
notification. The default state is enabled.
Only Administrator or operator-level users can issue this command.