Register Descriptions
Function Code*
(COM4-COM0)
4 3 2 1 0
1 0 0 0 0
1 0 0 1 1
1 1 0 1 1
1 1 1 0 0
1 1 1 0 1
1 1 1 1 0
1 0 1 1 0
1 1 1 1 1
1 0 1 1 1
1 0 1 0 0
* CNT[2-0] set to 000 binary
** Represents all eight bits of the Auxiliary Mode Register
GPIB-1014P User Manual
Table 4-4. Auxiliary Command Summary (continued)
Hex
Code**
10
13
1B
1C
1D
1E
16
1F
17
14
Auxiliary Command
Go To Standby
Listen
Listen in Continuous Mode
Local Unlisten
Execute Parallel Poll
Set IFC
Clear IFC
Set REN
Clear REN
Disable System Control
4-30