Section Three

Interrupt Status/ID Vector Selection

Switches located at U7 configure the interrupt status/ID vector, which is provided by the GPIB-
1014P during an interrupt acknowledge cycle. This interrupt vector consists of eight bits, labeled
V0 through V7, as shown in Figure 3-6. Bit V7 corresponds to the most significant bit while V0
corresponds to the least significant. Press the side labeled 0 to select a logical zero for the
corresponding address bit. Press the side labeled 1 to select a logical one. Figure 3-6 shows the
configuration for a status/ID byte value 1A hex.
Key
This side down for logic 1
© National Instruments Corporation
= the side you press down for Status/ID Byte 1A hex

Figure 3-6. Status/ID Byte 1A hex

3-7
This side down for logic 0
V7
V6
1
V5
V4
V3
V2
A
V1
V0
U7
Configuration and Installation
GPIB-1014P User Manual