Diagnostics and Troubleshooting

GPIB-1014P Hardware Installation Tests

1. Initialize TLC.
B
AUXMR = 2
B
AUXMR = 0
2. Send Chip Reset, then read registers and compare to reset values.
B
AUXMR = 2
3
ISR1 = 0?
5
ISR2 = 0?
7
SPSR = 0?
9
ADSR = 40?
B
CPTR = 0?
3. Test ton, DO, ERR, CPTR, TA.
B
AUXMR = 2
9
ADMR = 80
B
AUXMR = 0
9
ADSR = 42?
3
ISR1 = 2?
1
CDOR = 51
B
CPTR = 51?
3
ISR1 = 6?
3
ISR1 = 0?
B
AUXMR = 2
9
ADMR = 0
B
AUXMR = 0
9
ADSR = 40?
4. Check lon, LA.
B
AUXMR = 2
3
IMR1 = 0
5
IMR2 = 0
9
ADMR = 40
B
AUXMR = 0
9
ADSR = 44?
B
AUXMR = 2
9
ADSR = 40?