WAGO 750-306 Technical Description page 128

Modular i/o system devicenet
Hide thumbs Also See for 750-306:
Table of Contents

Advertisement

128 • DeviceNet
Configuration / Parametering with the Object Model
14
15
16
17
18
19
20
21
22
23
24
25
26
40
specific
get/set
BK_SEL_S
TORED_CO
SCYC_C_P
ATH
specific
get/set
BK_EM_ex
pected_pac
ket_rate
specific
get/set
BK_EM_wa
tchdog_tim
eout_action
specific
get/set
BK_PIO_ex
pected_pac
ket_rate
specific
get/set
BK_PIO_w
atch-
dog_timeou
t_action
specific
get/set
BK_BS_ex
pected_pac
ket_rate
specific
get/set
BK_BS_wa
tchdog_tim
eout_action
specific
get/set
BK_COS_e
xpected_pa
cket_rate
specific
get/set
BK_COS_
watch-
dog_timeou
t_action
specific
get/set
BK_BOI
specific
get/set
BK_DO_FA
ULT_REAC
TION_ON_
RELEASE_
PIO
specific
get/set
BK_DO_FA
ULT_REAC
TION_ON_
RELEASE_
COS
specific
get/set
BK_DO_FA
ULT_REAC
TION_ON_
RELEASE_
ST
specific
get/set
BK_static_
ana-
log_digital_i
nput_mappi
ng
only instance values that are available for
Couplers present module configuration (e.g.
do not use analog input points if only digital
modules are fixed to the Coupler.
UINT
Non volatile power up value for the change of
state and cyclic connection path. The attribute
is used to hold an enumerator for the assem-
bly path and the class and instance for modu-
les object (discrete input point...) paths. Write
only instance values that are available for
Couplers present module configuration (e.g
Digital Ausgang not use analog input points if
only digital modules are fixed to the Coupler.
UINT
Defines the default timing associated with
this Explicit Messaging Connection
USINT
Defines how to handle Inactivity/Watchdog
Explicit Messaging Connection timeouts
UINT
Defines the default timing associated with
this Poll I/O Connection Connection
USINT
Defines how to handle Inactivity/Watchdog
Poll I/O Connection Connection timeouts
UINT
Defines the default timing associated with
this Bit–Strobe I/O Connection Connection
USINT
Defines how to handle Inactivity/Watchdog
Bit–Strobe I/O Connection Connection time-
outs
UINT
Defines the default timing associated with
this Change of State and Cyclic I/O Connec-
tion
USINT
Defines how to handle Inactivity/Watchdog
Change of State and Cyclic I/O Connection
timeouts
USINT
Defines the default value for BOI(Obj0x3
Inst. 1 Att. 3. It handles the CAN Bus-Off
situation.
0: Hold the CAN chip in its bus-off (reset)
state upon detection of a bus-off indication
1: If possible, fully reset the CAN chip and
continue communicating upon detectionof a
bus-off indication
USINT
Defines the behavior after de allocation the
polled I/O connection
0: (default) do nothing
1: Process the Coupler fault reaction
USINT
Defines the behavior after de allocation the
Change of State and Cyclic I/O Connection
0: (default) do nothing
1: Process the Coupler fault reaction
USINT
Defines the behavior after de allocation the
strobed Connection
0: (default) do nothing
1: Process the Coupler fault reaction
UINT
Defines how to calculate the values for the
number of analog and digital input bits.
0000: All bits are digital
0016: One word is analog remaining bits are
digital
0032: Two words are analog remaining bits
are digital
...
0xFFFF: All bits are handled like module type
WAGO-I/O-SYSTEM 750
DeviceNet