WAGO 750-306 Technical Description page 126

Modular i/o system devicenet
Hide thumbs Also See for 750-306:
Table of Contents

Advertisement

126 • DeviceNet
Configuration / Parametering with the Object Model
I/O Connection Object State
Get_Atribute/
Set_Attribute/
Apply_Attributes
Get_Atribute/
Set_Attribute/
Apply_Attributes/
Reset/Message
Produced/Consumed
5.6.2.1.7 Acknowledge Handler Object (0x2B):
Instance 0:
Attribute
ID
1
2
Instance 1:
Attribute
ID
1
2
3
Services:
Service Code
0x0E
0x10
Non-Existent
Create
Configuring
Apply_Atributes
Established
Inactivity/Watchdog
Timeout & watchdog_timeout_action =
Reset
Transition to Time Out
Delete
Timed Out
Used in
Access
buscoupler
rule
required
get
required
get
Used in
Access
buscoupler
rule
get/set
required
required
get/set
required
get
Service Name
Get_Attribute_Single
Set_Attribute_Single
Delete from any state
Waiting for
Apply_Atributes
Connection ID
Name
Data type
Description
Revision
UINT
Revision of the Identity Object,
Range 1-65535, class definition
upon which the implementation is
based.
Max
UINT
maximum instance number of an
instance
object currently created in this
class level of device
Name
Data type
Description
Acknow-
UINT
time to wait for acknowledge before resen-
ledge
ding range 1-65,535 ms (0 invalid), default 16
timer
ms
Retry limit USINT
number of ack timeouts to wait before infor-
ming the producing application of a RetryLi-
mit_Reached event default=1, range 0-255;
default 16 ms
COS
UINT
0x04, connection instance which contains the
Producing
path of the producing I/O application object
Connec-
which will be notified of ack handler objects
tion
Instance
Description
Used to read a DeviceNet Object attribute
value
Used to modify a DeviceNet object attribute
value
Get_Atribute/Set_Attribute
Apply Atributes
WAGO-I/O-SYSTEM 750
DeviceNet
Value
0x01
0x02
Value