Developer Thermistor - Kodak X-Omat 2000 Service Manual

Hide thumbs Also See for X-Omat 2000:
Table of Contents

Advertisement

13.9 cm
(5.500 .060 in.)
[8] Use the HEATER LOCATOR on the THERMOWELL to check the correct location of the DEVELOPER
HEATER.
Caution
Do not tighten the DEVELOPER HEATER excessively or you will cause damage to the THERMOWELL.
[9] Use your hand to tighten the DEVELOPER HEATER, then tighten the DEVELOPER HEATER an additional
1/2 rotation.
[10] Install the THERMOWELL using 2 SCREWS.
[11] Connect the wires of the DEVELOPER HEATER at TB2-9 and TB2-10.
[12] Close the ELECTRICAL BOX.
[13] Fill the DEVELOPER TANK or remove the CLAMPS from the TUBES on the THERMOWELL.

DEVELOPER THERMISTOR

Warning
Dangerous Voltage
[1] Disconnect the main power.
[2] Drain the DEVELOPER TANK or apply CLAMPS to the 2 TUBES on the THERMOWELL. See the Figure
on Page 34.
ESD
Possible damage from electrostatic discharge.
[3] Open the ELECTRICAL BOX.
[4] Disconnect the wires of the DEVELOPER THERMISTOR at TB4-13 and TB4-14.
Warning
When you remove the DEVELOPER THERMISTOR from the THERMOWELL, there might be a leakage of
solution. Clean all spills.
[5] Remove the DEVELOPER THERMISTOR from the THERMOWELL.
[6] Apply SEALANT TL-3230 to the THREADS on the new DEVELOPER THERMISTOR.
7C8772 – 12JAN99
5 mm
(13/64 in.)
HEATER LOCATOR
Adjustments and Replacements
DEVELOPER
HEATER
THERMOWELL
60
HEATER
LOCATOR
H172_1050BCA
H172_1050BA
35

Hide quick links: