Developer Over-Temperature Thermostat - Kodak X-Omat 2000 Service Manual

Hide thumbs Also See for X-Omat 2000:
Table of Contents

Advertisement

SERVICE MANUAL
DEVELOPER
THERMISTOR
Caution
You must install the DEVELOPER THERMISTOR at the correct distance from the THERMOWELL.
[7] Install the new DEVELOPER THERMISTOR 4 mm (5/32 in.) from the THERMOWELL.
[8] Connect the wires of the new DEVELOPER THERMISTOR at TB4-13 and TB4-14.
[9] Close the ELECTRICAL BOX.
[10] Fill the DEVELOPER TANK or remove the CLAMPS from the TUBES on the THERMOWELL.

DEVELOPER OVER-TEMPERATURE THERMOSTAT

Warning
Dangerous Voltage
[1] Disconnect the main power.
[2] Drain the DEVELOPER TANK or apply CLAMPS to the 2 TUBES on the THERMOWELL. See the Figure
on Page 34.
ESD
Possible damage from electrostatic discharge.
[3] Open the ELECTRICAL BOX.
[4] Disconnect the wires of the DEVELOPER OVER-TEMPERATURE THERMOSTAT at:
• TB4-8
• TB4-9
• TB4-15
• TB4-16
Warning
When you remove the DEVELOPER OVER-TEMPERATURE THERMOSTAT from the THERMOWELL, there
might be a leakage of solution. Clean all spills.
[5] Remove the DEVELOPER OVER-TEMPERATURE THERMOSTAT from the THERMOWELL.
36
4 mm
(5/32 in.)
THERMOWELL
12JAN99 – 7C8772
H172_1051BCA
H172_1051BA