[10] Install:
• PUMP COVER
• 2 SCREWS
• TOP COVER
• RECEIVING BIN

PLUMBING System Replacements

DEVELOPER HEATER

Warning
Dangerous Voltage
[1] Disconnect the main power.
H172_1049BCA
H172_1049BC
[2] Drain the DEVELOPER TANK or apply CLAMPS to the 2 TUBES on the THERMOWELL.
ESD
Possible damage from electrostatic discharge.
[3] Open the ELECTRICAL BOX.
[4] Disconnect the wires of the DEVELOPER HEATER at TB2-9 and TB2-10.
Warning
When you remove the DEVELOPER HEATER from the THERMOWELL, there might be a leakage of solution.
Clean all spills.
[5] Remove:
• 2 SCREWS
• THERMOWELL
• DEVELOPER HEATER from the THERMOWELL
[6] Apply SEALANT TL-3230 to the THREADS on the new DEVELOPER HEATER.
[7] Insert the new DEVELOPER HEATER into the THERMOWELL.