SERVICE MANUAL
HEAT EXCHANGER
Purpose:
Use this procedure for the replacement of the HEAT EXCHANGER for the FIXER TANK or the
WASH TANK.
2 SCREWS
2 TANK
CLIPS
38
RACK
SUPPORT
2 TANK
SEALS
H172_1053CCA
H173_1053CA
Warning
Dangerous Voltage
[1] Disconnect the main power.
[2] Disconnect the water supply to the PROCESSOR.
[3] Remove:
• TOP COVER
• 2 SIDE PANELS
[4] Drain the 3 TANKS.
[5] Remove:
• 2 SCREWS
• RACK SUPPORT
• TANK SEALS
• TANK CLIP
[6] Disconnect all TUBING from the TANK.
12JAN99 – 7C8772