Recirculation Pump
Removing and Replacing the Recirculation Pump
[1]
Disconnect the main power.
[2]
Remove the SPLASH COVER over the PUMP. See Figure 39 on page 2-36.
[3]
Disconnect the CONNECTOR P11 from the ELECTRICAL BOX.
[4]
Use PINCH CLAMPS on the TUBING to prevent solution from leaking.
[5]
Disconnect the TUBING from the RECIRCULATION PUMP.
[6]
Remove the MOUNTING BOLTS and the RECIRCULATION PUMP.
[7]
Reverse the above procedure to install the RECIRCULATION PUMP.
Installing an O-Ring
[1]
Use PINCH CLAMPS on the TUBING to prevent solution from LEAKING.
[2]
Remove the WING NUTS and OUTER PUMP HOUSING. See Figure 39 on page 2-36.
[3]
Install a new O-RING SEAL.
246628
SECTION 4
Plumbing
Dangerous voltage.