Plumbing; Recirculation Pump; Removing And Replacing The Recirculation Pump; Installing An O-Ring - Kodak M6B Service Manual

Rp x-omat processor
Table of Contents

Advertisement

Recirculation Pump

Removing and Replacing the Recirculation Pump

[1]
Disconnect the main power.
[2]
Remove the SPLASH COVER over the PUMP. See Figure 39 on page 2-36.
[3]
Disconnect the CONNECTOR P11 from the ELECTRICAL BOX.
[4]
Use PINCH CLAMPS on the TUBING to prevent solution from leaking.
[5]
Disconnect the TUBING from the RECIRCULATION PUMP.
[6]
Remove the MOUNTING BOLTS and the RECIRCULATION PUMP.
[7]
Reverse the above procedure to install the RECIRCULATION PUMP.

Installing an O-Ring

[1]
Use PINCH CLAMPS on the TUBING to prevent solution from LEAKING.
[2]
Remove the WING NUTS and OUTER PUMP HOUSING. See Figure 39 on page 2-36.
[3]
Install a new O-RING SEAL.
246628
SECTION 4

Plumbing

Dangerous voltage.
2-35

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents