(5) Disconnect the registration front/rear sensor harness, T1 paper feed sensor harness and
the MP paper empty sensor harness from the high-voltage power supply PCB ASSY to
remove the high-voltage power supply PCB ASSY.
(6) Disconnect the HVPS flat cable from the high-voltage power supply PCB ASSY.
Assembling Note:
• Fold the HVPS flat cable at the positions shown in the figure below.
Mountain fold
Valley fold
Main PCB
Conductor
side
MP paper empty sensor harness
T1 paper feed sensor harness
Fig. 3-87
221±1
45°
Fig. 3-88
3-98
HVPS flat cable
Registration front/rear sensor
harness
High-voltage power
supply PCB ASSY
90±1
58±1
HVPS
Conductor
45°
side
Confidential