Error code C800
The memory size allotted for Secure Print was exceeded when saving Secure Print data.
<User Check>
• Print the print data stored in the memory.
• Divide the print data and print them separately.
Step
1
Main PCB failure
Error code D800
An error occurred while initializing the touch panel.
Step
Panel firmware version and
1
main firmware version do not
match
Connection failure of the panel
2
PCB flat cable
3
LCD relay PCB failure
4
Main PCB failure
Error code E000
An error occurred in the ROM check sum.
Error code E100
Program error
Step
Malfunction of the main
1
firmware
2
Main PCB failure
Cause
Replace the main PCB ASSY.
Cause
Install the latest main firmware.
Reconnect the panel PCB flat cable.
Replace the LCD panel ASSY.
Replace the main PCB ASSY.
Cause
Install the latest main firmware.
Replace the main PCB ASSY.
2-82
Remedy
Remedy
Remedy