Brother HL-L5000D Service Manual page 357

Hide thumbs Also See for HL-L5000D:
Table of Contents

Advertisement

<Operating Procedure>
Non touch panel models
(1) Press the [▲] or [▼] key in the initial
state of maintenance mode to display
"MAINTENANCE 10" on the LCD.
(2) Press the [OK] key. "WSW00" is
displayed on the LCD, indicating that
the machine is ready for worker switch
number entry.
(3) Press the [▲] or [▼] key to display the
worker switch number for which you
want to change the setting on the
LCD.
(4) Press the [OK] key. The following
message is displayed on the LCD,
and selector No.1 flashes.
Selector No. 1
WSWXX = 0 0 0 0 0 0 0 0
(5) Pressing the [▲] key enters "1", and
pressing the [▼] key enters "0". Press
either to enter desired number to
Selector No.1. The next digit starts
flashing.
(6) Keep entering numbers to Selector
No.8 using the [▲] or [▼] key as
described in the procedure (5).
(7) Press the [OK] key. The new selector
setting value is stored in the
EEPROM, and the LCD returns to the
ready state for worker switch number
entry ([WSW00]).
(8) When all switch setting is completed,
press the [OK] or [X] key to return the
machine to the initial state of
maintenance mode.
Note:
• To cancel operation and return to the initial state of maintenance mode, press the [X] key.
• If there is no entry for one minute or longer on 2-digit worker switch number selection after
the first digit was entered, the machine returns to the initial state of maintenance mode
automatically.
Touch panel models
(1) Press the [1], and then the [0] key in the
(2) Enter the worker switch number that
(3) Press the [ ] or [ ] key to move the
Selector No. 8
(4) When changing the setting is
(5) When all switch setting is completed,
5-8
initial state of maintenance mode.
"WSW00" is displayed on the LCD.
you want to change the setting.
The following display appears on the
LCD.
Selector No. 1
WSWXX = 0 0 0 0 0 0 0 0
cursor to the desired selector, and
change the setting by pressing the [1]
or [0] key.
completed, press the [SET] key. The
new selector setting value is stored in
the EEPROM, and the LCD returns to
the ready state for worker switch
number entry ("WSW00").
press the [X] key to return the
machine to the initial state of
maintenance mode.
Selector No. 8
Confidential

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents