O.ERR_70
SyncPos
Error in DIM command
Meaning
The definition of an array in a DIM command does
not correspond to an already existing array in the
SyncPos option.
Cause
The fields are from older SyncPos programs. The
current program has other definitions.
Tip
Either adapt the SyncPos program to the correct
array size or delete the old arrays with
"CONTROLLER" → "MEMORY" → "DELETE
E E PRO M".
N B!
Remember to follow the recommendations
concerning saving programs and parameters
before deleting the EEPROM.
O.E R R_71
SyncPos
Attempt was made to cross arraybounds
Meaning
An attempt was made to describe an array ele-
ment that is located outside of the defined array
limits.
Cause
Error in the SyncPos program. Array sizing does not
agree with the space required (e.g. due to an in-
correctly programmed loop).
Or the array is too small for the number of test runs
triggered by TESTSTART.
Tip
Check loop variables.
O.E R R_79
SyncPos
Timeout while waiting for index.
Meaning
The command WAITNDX was executed and the
timeout listed was exceeded.
Cause
The timeout is probably too short or the index
impulse could not found (see also O.ERR_9).
210
Programmable SyncPos motion controller
O.ER R_84
SyncPos
Too many time interrupts
Meaning
Too many ON TIME or ON PERIOD commands
were used within the program.
Tip
A maximum of 12 of these ON TIME and/or ON
PERIOD commands are allowed within one
program. . . . .
O.E RR_87
SyncPos
No more space for variables
Meaning
When the SyncPos program is started the space
for the necessary variables is reserved dynamically.
This space is now no longer available.
Cause and tip
You may have selected a maximum number of
variables which is too high. Reduce the maximum
number in "SETTINGS" → "COMPILER" (Standard
= 92).
Or the memory available is occupied with pro-
grams or arrays. Delete the programs with
"CONTROLLER" → "PROGRAMS" → "DELETE
ALL"
or delete both the programs and arrays, i.e. by
deleting the entire memory with "CONTROLLER"
→ "ME MORY" → "DELETE EEPROM". . . . .
N B!
Remember to follow the recommendations
concerning saving programs and parameters
before deleting the EEPROM.
O.E R R_90
SyncPos
MEMORY locked
Meaning
The program memory is write-protected and
cannot be altered.
Tip
This means that autorecognition can neither be set
nor deleted and programs can neither be saved or
deleted. Equally, → "RAM SAVE" and →
"EEPROM DELETE" will not be executed.