■ ■ ■ ■ ■ VLT parameter list
PNU Parameter
description
700
System control
701
Program number
702
PID, Proportional factor
703
PID, Derivative factor
704
PID, Integral factor
705
PID, Integral bandwidth
706
PID, BANDWIDTH
707
PID, Velocity Feed-forward
708
PID, Acceleration Feed-forward
709
PID, Velocity filter
710
User parameter 10
711
User parameter 11
...
778
User parameter 78
779
User parameter 79
780
Activated dead time compensation
(Not available in VLT5000Flux)
781
Program ID
795
User parameter 95 (read only)
796
User parameter 96 (read only)
797
User parameter 97 (read only)
798
User parameter 98 (read only)
799
User parameter 99 (read only)
Changes during operation
"Yes" means that the parameter can be changed, while the VLT frequency converter is in operation. "No"
means that the VLT frequency converter must be stopped before a change can be made.
4-Setup
"Yes" means that the parameter can be programmed individually in each of the four setup's, i.e. the same
parameter can have four different data values. "No" means that the data value will be the same in all four
setup's.
Conversion index
The conversion index is used when transferring parameter values with decimals by means of serial commu-
nication. Conversion index 0 means that the parameter value is multiplied by 1.
Data type
Indicates the data type of the parameter value. Data type 4
1 1 1 1 1 6bit
6bit.
6bit
6bit
6bit
1) The maximum range is -2
meter in the application program using LINKGPAR or LINKAXPAR.
170
Factory
settings
0
-1
30
0
0
1000
1000
0
0
0
0
0
0
0
OFF
0
0
0
0
0
0
Data type 4
Data type 4
Data type 4
Data type 4 is an Integer 3
32
32
to 2
-1 (-2147483648 to 2147483647) but the actual range is specified when defining a user para-
Programmable SyncPos motion controller
Range
Changes
during
Operation
0 ... 2
Yes
-1 ... 127
Yes
0 ... 65000
Yes
0 ... 65000
Yes
0 ... 65000
Yes
0 ... 1000
Yes
0 ... 65000
Yes
0 ... 65000
Yes
0 ... 65000
Yes
–500000 ... 500000
Yes
Defined by user
1
Yes
Defined by user
1
Yes
Defined by user
1
Yes
1
Defined by user
Yes
0 ... 1
No
0...1000
No
Defined by user
1
Read only
Defined by user
1
Read only
1
Defined by user
Read only
1
Defined by user
Read only
Defined by user
1
Read only
Integer 3
Integer 3
Integer 3
Integer 32bit
2bit and data type 6
2bit
2bit
2bit
MG. 1 0.J8.02 – VLT is a registered Danfoss trade mark
4-Setup
Con- Data
version type
index
No
0
6
No
0
4
No
0
4
No
0
4
No
0
4
No
0
4
No
0
4
No
0
4
No
0
4
No
0
4
No
0
4
No
0
4
No
0
4
No
0
4
No
0
6
No
0
6
No
0
4
No
0
4
No
0
4
No
0
4
No
0
4
data type 6
data type 6
data type 6 is an Unsigned
data type 6
Unsigned
Unsigned
Unsigned
Unsigned