Parameter Code
Parameter Name
KINT
Integral value for PID control
KPROP
Proportional value for PID control
MENCODER
Resolution of the encoder 1 (master)
MENCODERTYPE Encoder type for encoder 0 (Master)
N EG LI M IT
Negative software limit switch
O_AXMOVE
Output for motion command active
O_B RAKE
Output for mechanical brake
O_E R RO R
Output for error
POSDRCT
Rotational direction
PO SE R R
Maximum tolerated position error
POSFACT_N
Denominator user factor
POSFACT_Z
Numerator user factor
POS LI MIT
Positive software limit switch
PRGPAR
Activated program number
PROFTIME
Scan time for profile generator
RAMPMIN
Shortest ramp
RAM PTYP E
Ramp type
R EGWMAX
Size of the control window (activation)
R E GWM I N
Size of the control window (deactivation)
R EVE RS
Reverse behavior for slave
SWN EG LI MACT
Negative software limit switch active
SWPO SLI MACT
Positive software limit switch active
SYNCACCURACY Size of the precision window for position synchronization 55
SYNCFACTM
Synchronization factor master (M:S)
SYNCFACTS
Synchronization factor slave (M:S)
SYNCFAULT
Marker number for fault
SYN CMAR KM
Marker number for master
SYNCMARKS
Marker number for slave
SYNCMFTIME
Defines filter time for marker correction
SYNCMFPAR
Marker filter configuration
SYNCMMAXCORR Limits max. correction done by marker correction
SYNCMPULSM
Marker interval for master
SYN CM PU LS S
Marker interval for slave
SYNCMSTART
Start behavior for marker synchronization
SYNCMTYPM
Marker type for master
SYNCMTYPS
Marker type for slave
SYN CMWI N M
Tolerance window for master marker monitoring
SYNCMWINS
Tolerance window for lave marker monitoring
SYNCOFFTIME
Compensation velocity of an offset
SYNCPOSOFFS
Position offset for positioning synchronization
SYNCREADY
Marker number for ready
SYNCTYPE
Type of synchronization: normal or with look ahead
SYNCVELREL
Tolerated deviance of the slave drive
from the master velocity in %
SYNCVFTI ME
Velocity filter
TESTTI M
Time in target window
TESTVAL
Limit value for reading in target window
TESTWI N
Size of target window
T I M E R
Sampling time for PID control
VE LMAX
Maximum velocity
VELMAXQC
Maximum velocity (internal parameter)
VELRES
Velocity resolution
172
Programmable SyncPos motion controller
VLT- SyncPos
Par.
No. Par.No.
Group
704
13
AXR
702
11
AXR
30
AXE
67
AXE
4
AXI
64
AXI
48
AXI
108
G LS
28
AXE
15
AXR
26
AXE
23
AXE
5
AXI
701
102
G LS
29
AXE
31
AXV
32
AXV
38
AXR
39
AXR
63
AXR
19
AXI
20
AXI
AXS
49
AXS
50
AXS
57
AXS
52
AXS
53
AXS
18
AXS
17
AXS
6
AXS
58
AXS
59
AXS
62
AXS
60
AXS
61
AXS
68
AXS
69
AXS
16
AXS
54
AXS
56
AXS
51
AXS
66
AXS
709
65
AXS
24
AXI
25
AXI
8
AXI
14
AXR
1
AXV
9
AXV
22
AXV
MG. 1 0.J8.02 – VLT is a registered Danfoss trade mark
Unit
Factory
Setting
0
30
counts/rev.
500
0
q c
–500000
0
0
0
1
q c
20000
1000
1000
q c
500000
– 1
msec
1000
msec
1000
0
q c
0
q c
0
0
0
0
q c
1000
q c
1
q c
1
10
1
1
msec
0
0
qc
0
qc
500
q c
500
0
0
0
q c
0
qc
0
msec
0
qc
0
1
0
%
0
τ_filt (µsec)
0
ms
0
q c
1
q c
0
msec
1
Rpm
3000
qc/ms *
1/65536