Input/Output Commands (I/O)
Commands for setting and re-setting the outputs,
reading the inputs, reading movement information,
reading system data and entering and outputting
user information.
APOS
reads actual position
AXE N D
reads info on status of program
execution
CPOS
reads set position
MAPOS
queries actual position of the
master
M I PO S
queries last index or marker
position of the master
IPOS
queries last index or marker
position of the slave
MAVE L
queries actual velocity of the
master
AVE L
queries actual velocity of an
axis
TRACKE R R
queries actual position error of
the axis
SYNCER R
queries actual synchronization
error of the slave
E R R N O
reads error number
I N
reads input bit-by-bit (individually)
I N B
reads input by bytes (units of 8)
INAD
reads analog input
I N KEY
reads key codes of VLT
OUT
sets output bit-by-bit (single)
OUTAN
sets VLT reference
OUTB
sets output by bytes (units of 8)
OUTDA
sets analog output (freely available)
PI D
completes PID calculation
PR I NT
output (display) texts and
variables
STAT
reads axis status
TESTSETP
Specify recording data for test run
TESTSTART
Start the recording of a test run
T I M E
reads internal controller time
_G ETVE L
changes sample time for AVEL
and MAVE L
MG.10.J8.02 – VLT is a registered Danfoss trade mark
Programmable SyncPos motion controller
Interrupt Functions (INT)
DISAB LE ...
switches interrupt ... off
DISAB LE ALL
switch off all interrupts except
ON ER ROR
ENAB LE ...
switches interrupt ... on
ENAB LE ALL
switches all interrupts on
ON APOS .. GOSUB
call up a subprogram when the
slave position xxx is
ON DELETE .. GOSUB
Deletes a position-interrupt: ON
APOS, ON MCPOS or ON MAPOS
ON COMBIT .. GOSUB
call up a subprogram when Bit n of
the communication buffer is set
ON ERROR GOSUB
calls subroutine in the event of
an error
ON IN .. GOSUB calls subroutine depending on
input signal
ON MAPOS .. GOSUB
call up a subprogram when the
master position xxx (qc) is
passed.
ON MCPOS .. GOSUB
call up a subprogram when the
master position xxx (MU) is
passed.
ON PARAM .. GOSUB
call up a subprogram when a
parameter is altered
ON PERIOD .. GOSUB
calls subroutine at regular intervals
ON STATB IT
call up a subprogram when bit n
of the VLT status is set
ON TIME
calls subroutine after single
timing
passed.
97