Markers Button Bar; Markers - L3Harris Narda SignalShark User Manual

Table of Contents

Advertisement

3. In the Markers tab of the Marker Config window, tap a marker from the list.
– or –
Tap Marker No. in the Button bar and select a marker from the dropdown list.
The editable parameters are displayed in the Button bar.
4. Tap the Enabled button to switch between Yes and No.
5. Tap the Type button to switch between Normal and Delta.
6. Tap the Freq. Link button and select a Marker No. from the dropdown list.
7. Tap the Function button and select the required option from the dropdown list: Ch. Power
(Channel Power), Noise, Occ. BW (Occupied Bandwidth), Transmitter.
8. Tap the M1 as Ref. for all Delta Markers button to select M1 as a reference.
9. Select another tab to change further settings (see following topics).
10. To close the Marker Config menu, press the Esc key or tap the header of the button bar.

Markers button bar

In the Markers button bar, following settings are available:
Tab
Marker No.
Enabled
Type
Ref.
Trace
Freq. Link
Time Link
Function
M1 as ref.
for all Delta Markers

Markers

Shows the eight markers and their current settings.
Select tab in the Marker Config window.
Select a marker to be set.
Enable/disable marker.
A disabled marker is not displayed, but all settings are
retained.
Set marker type to Normal or Delta.
Referenced marker if marker is set to delta.
Trace which the marker refers to.
Two markers can be linked via a fixed frequency.
Two markers can be linked via a fixed time.
Assign a function to a marker.
Set marker 1 as reference for all delta markers.
Using Markers
69

Advertisement

Table of Contents