Frequency Enter a frequency as marker position.
Time
Enter a time as marker position.
Value
Enter an absolute power level as marker position.
Search
The Search menu allows to set various parameters for setting markers to a peak, e.g. when
tapping the Next Peak button.
Spectrogram
Search Range
Track Peaks
Auto peak Search
for M1
Exclude LO
Peak Excursion
Use Search Limits
Lower Frequency
Upper Frequency
Threshold
All / Visible: Select to search all data or just the visible data.
Marker is fixed to a peak even if the frequency varies.
Marker 1 always shows highest peak.
Only frequencies higher than 4 x RBW are evaluated. Low
frequencies, DC portion, and mirror frequencies are excluded.
Peak Excursion determines what is considered a peak in contrast to
noise.
Narrow the search range:
• Lower Frequency: Set lower frequency limit
• Upper Frequency: Set upper frequency limit
• Threshold: Set the lower power level
Shows lower frequency limit
Shows upper frequency limit
Shows the lower power level
Using Markers
71