The Protection probe can be viewed by entering Info mode and scrolling to Temps.
Once in temps, the lower right selection button is blinking. Press, and the protection
probe displays rather than the Bot display. The displayed temp should be quite a bit
higher than the main temp probe. If 999 displays, it indicates an open probe.
Before pressing the lower right button
<= TEMPS =>
Main Lvl Bot
348° 331° 287°
5 5 . . 6 6 . . 2 2 R R e e p p l l a a c c e e m m e e n n t t
After pressing the lower right button
<= TEMPS =>
Main Lvl PPrb
348° 331° 462°
1. Lift the lid, tilt back and lock in to place.
2. Use a Phillips head screwdriver to
loosen
the
heating
spreaders.
3. Use a Phillips head bit to remove the
screws from the left-hand (from the
front of the unit) side panel.
4. Remove the side panel and set aside.
5. Use a 1/2 inch wrench to loosen the
compression fitting.
6. Pull the thermocouple from the fitting.
element
75