Error
Cause
NOT DE-
TECTED
E-84D
Cannot open lid - Pin
PRES-
is stuck and has not
SURE PIN
dropped down.
STUCK
Can open lid - wire
OR NOT
may be discon-
CONNEC-
nected or monitoring
TED
switch failed.
E-86B
Sticking solenoid.
PRES-
Clogged pressure
SURE
exhaust port.
STUCK
ON
Faulty pressure
transducer.
E-93 24V
2nd transformer dis-
DC
connected from
SUPPLY
control.
Short in drain motor
or selector valve
motor.
Correction
If lid pin is stuck, remove lid cover and manually free
pin.
•
Check wire connections and reconnect loose wires.
•
Replace faulty wires.
•
Test switch.
•
Replace switch if needed.
Test solenoid.
Check ports and unclog if necessary.
Test transducer.
•
Check transformer plug on back of control.
•
Check wire connections on 2nd transformer.
Test motors.
57