Error
Cause
FAILED
(Shorted)
E-19 PRO-
A setting in Tech
TECTION
Mode (T-40) speci-
PROBE
fies whether or not
FAILED
the fryer is equipped
with a protection
probe system. If the
T-40 option is set to
YES, and the control
does not detect a va-
lid reading on the
protection probe in-
put, an E-19 error is
generated.
E-41P-1-
System data lost.
LOST
Both the RAM copy
and stored copy of
the settings have
been lost. Settings
are reset to default.
E-41S
System data lost.
SYSTEM
Both the RAM copy
DATA
and stored copy of
LOST
the settings have
been lost. Settings
are reset to default.
E-46C IN-
Issue with microSD
TERNAL
chip.
SD MEM
ERR
E-46W
Unable to communi-
DATA
cate and save data
SAVE
to the microSD chip.
FAILED
Corrupt file.
E-47 ANA-
Problem reading the
LOG SYS-
A-to-D Analog to
TEM OR
Correction
Replace the protection probe. Once the error code is
acknowledged, the E-19 message goes away and nor-
mal operation resumes without the benefit of the pro-
tection probe feature. If the protection probe input is in
a continuously failed state, the E-19 error repeats
every 4 hours. If this E-19 error occurs in a fryer that
does not have and is not supposed to have a protection
probe installed, access Tech Mode and change the T-
40 option to NO.
Replace control board if occurs repeatedly.
Replace control board if occurs repeatedly.
Check to ensure chip is not ejected from slot.
Replace control board if occurs repeatedly.
Check 12 VDC and 5 VDC analog power supplies
Unplug pressure transducer at back of control.