Error
Cause
FAILED
(Shorted)
E-19 PRO-
A setting in Tech
TECTION
Mode (T-40) speci-
PROBE
fies whether or not
FAILED
the fryer is equipped
with a protection
probe system. If the
T-40 option is set to
YES, and the control
does not detect a va-
lid reading on the
protection probe in-
put, an E-19 error is
generated.
E-41P-1-
System data lost.
LOST
Both the RAM copy
and stored copy of
the settings have
been lost. Settings
are reset to default.
E-41S
System data lost.
SYSTEM
Both the RAM copy
DATA
and stored copy of
LOST
the settings have
been lost. Settings
are reset to default.
E-46C IN-
Issue with microSD
TERNAL
chip.
SD MEM
ERR
E-46W
Unable to communi-
DATA
cate and save data
SAVE
to the microSD chip.
FAILED
Corrupt file.
E-47 ANA-
Problem reading the
LOG SYS-
A-to-D Analog to
TEM OR
Correction
Replace the protection probe. Once the error code is
acknowledged, the E-19 message goes away and nor-
mal operation resumes without the benefit of the pro-
tection probe feature. If the protection probe input is in
a continuously failed state, the E-19 error repeats
every 4 hours. If this E-19 error occurs in a fryer that
does not have and is not supposed to have a protection
probe installed, access Tech Mode and change the T-
40 option to NO.
Replace control board if occurs repeatedly.
Replace control board if occurs repeatedly.
Check to ensure chip is not ejected from slot.
Replace control board if occurs repeatedly.
•
Check 12 VDC and 5 VDC analog power supplies
•
Unplug pressure transducer at back of control.