Error
E-10C
HIGH LIM-
IT
TRIPPED
E-10D
HIGH LIM-
IT
TRIPPED
E-10F
HIGH LIM-
IT
TRIPPED
E-10M
HIGH LIM-
IT
TRIPPED
52
Cause
High limit tripped
Check the error log to find out the vat temperature at
while cooking (Not
the time the high limit tripped. If this was several de-
simply in cook mode,
grees above the oil setpoint temperature, test for a
but with cook cycle
sticking contactor and replace if faulty. If the trip tem-
running).
perature was near the oil setpoint temperature, inspect
the high limit thermocouples for carbon build up and
clean if necessary. If no carbon found, see
Limit and Module Inspection , page 16
Limit Thermocouples Replacement , page
High limit tripped
Check the error log to find out the vat temperature at
the time the high limit tripped. If this was several de-
less than 5 minutes
after fryer was per-
grees above the oil setpoint temperature, test for a
forming an Auto-Fil-
sticking contactor and replace if faulty. If the trip tem-
ter or Quick Filter
perature was near the oil setpoint temperature, inspect
and the control re-
the high limit thermocouples for carbon build up and
turned to cook mode
clean if necessary. If no carbon found, see
on its own after de-
Limit and Module Inspection , page 16
tecting that the oil
Limit Thermocouples Replacement , page
was pumped up
(based on tempera-
ture rise on level
probe).
High limit tripped
Check the error log to find out the vat temperature at
while filtering (in-
the time the high limit tripped. If this was several de-
cluding Auto-Filter,
grees above the oil setpoint temperature, test for a
Daily Filter, Polish,
sticking contactor and replace if faulty. If the trip tem-
Dispose, Drain to
perature was near the oil setpoint temperature, inspect
Pan, Fill from Pan,
the high limit thermocouples for carbon build up and
etc.).
clean if necessary. If no carbon found, see
Limit and Module Inspection , page 16
Limit Thermocouples Replacement , page
High limit tripped
Check the error log to find out the vat temperature at
while fryer was in
the time the high limit tripped. If this temperature was
Melt Mode.
very low, this may be a sign that the vat was turned on
with low or no oil. If this was the case, fill the pot with
oil and reset the high limit. If the high limit tripped at a
higher temperature, inspect the high limit thermocou-
ples for carbon build up and clean if necessary. If no
carbon found, see
Correction
1.13 High
and
5.6 High
74.
1.13 High
and
5.6 High
74.
1.13 High
and
5.6 High
74.
1.13 High Limit and Module