Qty.
14061-
2
1
1
15210-
1
42
Description
Part #
KIT, LID CABLE
0
DEAD WEIGHT - 12
16903
PSI
GASKET-DEAD
94941
WEIGHT HOLDER
GASKET - STEAM
1
BOX COVER
When to Replace
Used to connect the lid assembly to the carriage
weight assembly in the back of the unit to offset
the lid weight. Replace cables when worn.
Used in the steam stack to regulate the pres-
sure inside the vat. Remove and clean monthly
or as needed. Replace if broken or lost.
The steam stack along with the dead weight
holder is removed and cleaned monthly. Re-
place the gasket if it is torn, brittle or lost.
The steam box is way to access the dead
weight and orifice to cleaned monthly. Replace
the gasket if it is torn, brittle or lost.