4. Follow red wire RHL 1 from the control board and make sure that it is securely
attached to the terminal on the lower module. If this wire is not connected,
reconnect it to match the diagram on the left.
5. Follow red wire RHL 2 from the control board and make sure that it is securely
attached to the terminal on the upper module. If this wire is not connected,
reconnect it to match the diagram on the left.
6. Make sure red wire HLJ connects the two modules as shown in the drawing on
the left.
7. Verify all other wires attached to the high limit modules have secure connections.
8. Continue to the next inspection or reinstall components as applicable.
1 1 . . 1 1 4 4 M M e e a a s s u u r r i i n n g g A A M M P P D D r r a a w w
Ensure that the amp draw of the fryer equals the amp draw listed on the data label.
Why is this important? If amp draw is less than what is on the data label, this would be
an indication that one of the phases that comes into the fryer may be missing, there
may be an issue with one of the contactors, or there may be an issue in one of the fire
bar heating elements.
H H I I G G H H V V O O L L T T A A G G E E P P R R E E S S E E N N T T ! ! T T h h i i s s p p r r o o c c e e d d u u r r e e s s h h o o u u l l d d o o n n l l y y
b b e e p p e e r r f f o o r r m m e e d d b b y y a a s s e e r r v v i i c c e e t t e e c c h h n n i i c c i i a a n n w w h h o o i i s s t t r r a a i i n n e e d d a a n n d d
u u n n d d e e r r s s t t a a n n d d s s e e l l e e c c t t r r i i c c a a l l s s a a f f e e t t y y . .