1 1 . . 1 1 7 7 . . 1 1 S S e e r r v v i i c c e e P P r r o o c c e e d d u u r r e e G G u u i i d d a a n n c c e e
Oil leaking in to drain pan.
Valve not moving but hear actuator moving.
22
ISSUE / SYMPTOM
1. Press and hold the menu button until
*MAIN* appears on the display.
2. Press the number one product button to
enter the filter menu.
3. Press the right arrow until 4. DRAIN ->
displays.
4. Select 4 4 . . D D R R A A I I N N - - > > .
5. Once all the oil drains into the drain
pan, visually inspect the drain and
valve.
6. Ensure the drain valve is fully open and
not partially closed, which indicates
the
valve
assembly
misaligned or needs replaced.
7. Select 5 5 . . F F I I L L L L < < - - .
8. Ensure the drain valve is fully closed
and not partially closed, which
indicates the valve assembly may be
misaligned or needs to be replaced.
9. Allow oil to fully fill the vat.
10. Once filled, cancel the filter pump
motor and exit out of the filter menu
by pressing and holding the menu
button.
11. Continue to the next inspection or
reinstall components as applicable.
SERVICE RECOMMENDATION
Replace drain valve.
Remove actuator and check for actuator
couple movement. Check if drain valve is
seized. Likely replace actuator only, valve
also if seized.
may
be