Error
Cause
E-10S
High limit tripped
HIGH LIM-
while vat was in
IT
Start-up Mode (not
TRIPPED
including Melt
mode), but not while
it was executing one
of the filter
operations.
E-10Y
High limit tripped
HIGH LIM-
less than 5 minutes
IT
after user responded
TRIPPED
YES to, Is Pot
Filled? question.
E-13A
Sensor failed or
PRES-
unplugged
SURE
SENSOR
FAILED
E-13B
Sensor failed or
PRES-
shorted to +5v
SURE
SENSOR
FAILED
Correction
Inspection , page 16
and
5.6 High Limit Thermocouples
Replacement , page
74.
Check the error log to find out the vat temperature at
the time the high limit tripped. If this temperature was
very low, this may be a sign that the vat was turned on
with low or no oil. If this was the case, fill the pot with
oil and reset the high limit. If the high limit tripped at a
higher temperature, inspect the high limit thermocou-
ples for carbon build up and clean if necessary. If no
carbon found, see
1.13 High Limit and Module Inspec-
tion , page 16
5.6 High Limit Thermocouples Re-
and
placement , page
74.
Check the error log to find out the vat temperature at
the time the high limit tripped. If this temperature was
very low, this may be a sign that the vat was turned on
with low or no oil. If this was the case, fill the pot with
oil and reset the high limit. If the high limit tripped at a
higher temperature, inspect the high limit thermocou-
ples for carbon build up and clean if necessary. If no
carbon found, see
1.13 High Limit and Module Inspec-
tion , page 16
and
5.6 High Limit Thermocouples Re-
placement , page
74.
A "good" reading from the sensor is between 0.5v (0
PSI) and 4.5v (30 PSI). Tolerances beyond those va-
lues are allowed:
- Low reference value less than 0.25v
- The "unplugged" condition should generate an E-
13A. A pull-down resistor on the CPU board pulls the
input low if disconnected.
Any E-13 error allows operators to cook on the fryer;
however, the control disables the pressure for the en-
tire cook cycle unless the E-13 condition resolves with
a good probe readings.
A "good" reading from the sensor is between 0.5v (0
PSI) and 4.5v (30 PSI). Tolerances beyond those va-
lues are allowed:
- High reference value more than 4.75v