Link Object, Instance Number: F6 hex
Supported services
Class
Table 4- 22
No.
1
2
3
Table 4- 23
No.
1
2
3
4
Fieldbuses
Function Manual, 04/2018, FW V4.7 SP10, A5E34229197B AE
• Get Attribute all
• Get Attribute single
Class Attribute
Service
Type
get
UINT16
get
UINT16
get
UINT16
Instance Attribute
Service
Type
Name
get
UINT32
Interface Speed
get
Interface Flags
get
ARRAY
Physical Address r8935 Ethernet MAC address
get_and_
Struct of
Interface Coun-
clear
ters
UINT32
In Octets
UINT32
In Ucast Packets
UINT32
In NUcast Pack-
ets
UINT32
In Discards
UINT32
In Errors
UINT32
In Unknown Pro-
tos
UINT32
Out Octets
UINT32
Out Ucast Pack-
ets
UINT32
Out NUcast
packets
UINT32
Out Discards
UINT32
Out Errors
Instance
Name
Revision
Max Instance
Num of Instances
Value/explanation
0:
link down,
10:
10 Mbps,
100: 100 Mbps
Bit 1: Link-Status
Bit 2: Duplex Mode (0: halb duplex, 1 duplex
Bit 3 ... 5: Automatic state identification
Bit 6: Reset required
Bit 7: Local hardware fault (0 = ok)
Optional, required if the "Media Counters Attribute"
is implemented.
Received octets
Received Unicast packets
Received non-Unicast packets
Incoming packets, not processed
Incoming packets with errors
Incoming packets with unknown protocol
Sent octets
Sent Unicast packets
Sent non-Unicast packets
Outgoing packets, not processed
Outgoing packets, with errors
Communication via EtherNet/IP
4.5 Supported objects
• Get Attribute all
• Get Attribute single
• Set Attribute single