Siemens SINAMICS G110M Function Manual page 121

Fieldbus systems
Hide thumbs Also See for SINAMICS G110M:
Table of Contents

Advertisement

Parameter number
Parameter numbers < 2000
Parameter numbers ≥ 2000
Table 5- 7
Parameter number
0000 ... 1999
2000 ... 3999
6000 ... 7999
8000 ... 9999
10000 ... 11999
20000 ... 21999
30000 ... 31999
60000 ... 61999
Indexed parameters
For indexed parameters, you must write the index as hex value into the subindex (IND
bit 7 ... 0).
Parameter contents
Parameter contents can be parameter values or connector parameters. You require two
words for connector parameters. You can find more information on interconnecting
connector parameters in the operating instructions of the Control Unit in the section
"Interconnecting signals in the inverter".
Enter the parameter value in the parameter channel right-justified as follows:
• 8-bit values:
• 16-bit values: Low word, bits 0 ... 15,
• 32-bit values: Low word and high word
Enter a connector parameter right-justified as follows:
• Number of the connector parameter:
• Drive object of the connector parameter:
• The index or bit field number of the connector parameter:
Fieldbuses
Function Manual, 04/2018, FW V4.7 SP10, A5E34229197B AE
PNU = parameter number.
Write the parameter number into the PNU (PKE bit 10 ... 0).
PNU = parameter number - offset.
Write the parameter number minus the offset into the PNU
(PKE bit 10 ... 0).
Write the offset in the page index (IND bit 15 ... 8).
Offset and page index of the parameter numbers
Offset
Page index
Hex
0
0 hex
2000
80 hex
6000
90 hex
8000
20 hex
10000
A0 hex
20000
50 hex
30000
F0 hex
60000
74 hex
Low word, bits
0 ... 7,
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10
0
0
0
1
0
0
1
0
0
0
0
1
1
0
1
0
1
0
1
1
1
0
1
1
bits 8 ... 15 are zero.
Communication via RS485
5.3 Communication via USS
Bit 9
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
1
0
0
0
1
0
1
0
High word
Low word, bits 10 ... 15
Low word, bits 0 ... 9
Bit 8
0
0
0
0
0
0
0
0
119