nodestat: By default, nodestat completes the following steps:
1. Gets the sshd,pbs_mom, xend port status.
2. If none of the ports are open, nodestat gets the fping status.
3. For pingable nodes that are in the middle of deployment, nodestat gets the deployment
status.
4. For non-pingable nodes, nodestat shows 'noping'.
– <power_state>: When the sate is not on or running, reports back the output of rpower
<noderange> stat command.
Example 3-15 "nodestat" output example with power option and all nodes that are turned on
# nodestat m601 -p
c250f06c01ap01-hf0: sshd
c250f06c01ap05-hf0: sshd
c250f06c01ap09-hf0: sshd
c250f06c01ap13-hf0: sshd
c250f06c01ap17-hf0: sshd
c250f06c01ap21-hf0: sshd
c250f06c01ap25-hf0: sshd
c250f06c01ap29-hf0: sshd
Example 3-16 "nodestat" output example with power option and all nodes are off
# nodestat m602 -p
c250f06c02ap01-hf0: noping(Not Activated)
c250f06c02ap05-hf0: noping(Not Activated)
c250f06c02ap09-hf0: noping(Not Activated)
c250f06c02ap13-hf0: noping(Not Activated)
c250f06c02ap17-hf0: noping(Not Activated)
c250f06c02ap21-hf0: noping(Not Activated)
c250f06c02ap25-hf0: noping(Not Activated)
c250f06c02ap29-hf0: noping(Not Activated)
Power management
The renergy power command is described in this section.
renergy
For this command, we list the help description as shown in Figure 3-6 on page 181. Typical
output examples are shown in Example 3-17 on page 183, Example 3-18 on page 183,
Example 3-19 on page 184, and Example 3-20 on page 184.
180
IBM Power Systems 775 for AIX and Linux HPC Solution