# renergy -h
Usage:
renergy [-h | --help]
renergy [-v | --version]
Power 6 server specific :
renergy noderange [-V] { all | { [savingstatus] [cappingstatus]
[cappingmaxmin] [cappingvalue] [cappingsoftmin] [averageAC] [averageDC]
[ambienttemp] [exhausttemp] [CPUspeed] } }
renergy noderange [-V] { {savingstatus}={on | off} | {cappingstatus}={on |
off} | {cappingwatt}=watt | {cappingperc}=percentage }
Power 7 server specific :
renergy noderange [-V] { all | { [savingstatus] [dsavingstatus]
[cappingstatus] [cappingmaxmin] [cappingvalue] [cappingsoftmin] [averageAC]
[averageDC] [ambienttemp] [exhausttemp] [CPUspeed] [syssbpower] [sysIPLtime]
[fsavingstatus] [ffoMin] [ffoVmin] [ffoTurbo] [ffoNorm] [ffovalue] } }
renergy noderange [-V] { {savingstatus}={on | off} |
{dsavingstatus}={on-norm | on-maxp | off} | {fsavingstatus}={on | off} |
{ffovalue}=MHZ | {cappingstatus}={on | off} | {cappingwatt}=watt |
{cappingperc}=percentage }
Blade specific :
renergy noderange [-V] { all | pd1all | pd2all | { [pd1status] [pd2status]
[pd1policy] [pd2policy] [pd1powermodule1] [pd1powermodule2] [pd2powermodule1]
[pd2powermodule2] [pd1avaiablepower] [pd2avaiablepower] [pd1reservedpower]
[pd2reservedpower] [pd1remainpower] [pd2remainpower] [pd1inusedpower]
[pd2inusedpower] [availableDC] [averageAC] [thermaloutput] [ambienttemp]
[mmtemp] } }
renergy noderange [-V] { all | { [averageDC] [capability] [cappingvalue]
[CPUspeed] [maxCPUspeed] [savingstatus] [dsavingstatus] } }
renergy noderange [-V] { {savingstatus}={on | off} |
{dsavingstatus}={on-norm | on-maxp | off} }
Figure 3-6 renergy command flag description
The renergy command remotely enables or disables Power7 energy features and displays
energy consumption statistics and features status. The following input and output values are
used:
Command: renergy <noderange> all
Flags:
– cappingmaxmin: Maximum and minimum power consumption values; is shown as
"cappingmax" and "cappingmin" values.
– cappingvalue: Power capping value setting; must be between the cappingmaxmin
values.
– averageAC: Average AC power consumption.
– averageDC: Average DC power consumption.
– ambienttemp: Ambient temperature in degrees Celsius near the CEC.
– exhausttemp: Exhaust temperature in degrees Celsius.
– CPUspeed: Actual CPU frequency in MHz.
Chapter 3. Monitoring assets
181