Figure A-3 ASMI memory deconfiguration window
When you verify any deconfigured resources, check that after the reference code, you see the
section called:
The first procedure listed is the FSPSP55. For more information about this procedure, see
IBM Power Systems Hardware Information Center at this website:
http://publib.boulder.ibm.com/infocenter/eserver/v1r3s/index.jsp
The fastest way to find the FSPSP55 isolation procedure is to search for it in the Information
Center. The procedure guides you to: Power Systems Information  POWER7 Systems 
9125-F2C  Troubleshooting, service and support  Isolation Procedures  Service
Processor Isolation Procedures  FSPSP55.
In this example, the requested Word 6 Data shows 000000000 and the procedure points to
the FRU callouts in the event. The first FRU includes the following location code:
U78A9.001.9912345-P1-R10
For more information about the FRU Location to A+ resource, see Table 5-4 on page 304.
Table 5-4 on page 304 shows U*-P1-R(9-40) is a QCM. In our example, R10, and in Table 5-5
on page 305 (QCM to OCTANT MAP), you see that U*-P1-R(9-12) is in octant 0. Figure A-4
on page 321 shows a view of the board layout for the octants.