IBM Power Systems 775 Manual page 203

For aix and linux hpc solution
Table of Contents

Advertisement

Attributes:
– <noderange>: Nodes that are listed in xCAT database that belong to a FSP/CEC
hardware type.
– <id_vm>: LPAR id such as the first lpar=1on OctantID=0, the first lpar=5 on
OctantID=1
– <physical_location_slot>: Physical location of PCI ports.
– <pending_pump_mode>: Pending configuration for pump mode (effective after IPL).
– <active_pump_mode>: Currently active pump mode.
– <installed_QPM>: Number of QPM physically installed.
– <pending_octant_config>: Pending octant configuration (effective after IPL).
– <active_octant_config>: Currently active octant configuration.
– <pending_interleave_mode>: Pending memory interleave mode (effective after IPL).
– <active_interleave_mode>: Currently active memory interleave mode.
Example 3-24 lsvm output example
# lsvm fsp
1: 520/U78A9.001.1122233-P1-C14/0x21010208/2/1
1: 514/U78A9.001.1122233-P1-C17/0x21010202/2/1
1: 513/U78A9.001.1122233-P1-C15/0x21010201/2/1
1: 512/U78A9.001.1122233-P1-C16/0x21010200/2/1
13: 537/U78A9.001.1122233-P1-C9/0x21010219/2/13
13: 536/U78A9.001.1122233-P1-C10/0x21010218/2/13
13: 529/U78A9.001.1122233-P1-C11/0x21010211/2/13
13: 528/U78A9.001.1122233-P1-C12/0x21010210/2/13
17: 553/U78A9.001.1122233-P1-C5/0x21010229/2/17
17: 552/U78A9.001.1122233-P1-C6/0x21010228/2/17
17: 545/U78A9.001.1122233-P1-C7/0x21010221/2/17
17: 544/U78A9.001.1122233-P1-C8/0x21010220/2/17
2: 521/U78A9.001.1122233-P1-C13/0x21010209/2/2
29: 569/U78A9.001.1122233-P1-C1/0x21010239/0/0
29: 568/U78A9.001.1122233-P1-C2/0x21010238/0/0
29: 561/U78A9.001.1122233-P1-C3/0x21010231/0/0
29: 560/U78A9.001.1122233-P1-C4/0x21010230/0/0
40.10.12.1: PendingPumpMode=1,CurrentPumpMode=1,OctantCount=8:
OctantID=0,PendingOctCfg=5,CurrentOctCfg=5,PendingMemoryInterleaveMode=2,CurrentMe
moryInterleaveMode=2;
OctantID=1,PendingOctCfg=1,CurrentOctCfg=1,PendingMemoryInterleaveMode=1,CurrentMe
moryInterleaveMode=1;
OctantID=2,PendingOctCfg=1,CurrentOctCfg=1,PendingMemoryInterleaveMode=1,CurrentMe
moryInterleaveMode=1;
OctantID=3,PendingOctCfg=1,CurrentOctCfg=1,PendingMemoryInterleaveMode=2,CurrentMe
moryInterleaveMode=2;
OctantID=4,PendingOctCfg=5,CurrentOctCfg=5,PendingMemoryInterleaveMode=2,CurrentMe
moryInterleaveMode=2;
OctantID=5,PendingOctCfg=1,CurrentOctCfg=1,PendingMemoryInterleaveMode=1,CurrentMe
moryInterleaveMode=1;
OctantID=6,PendingOctCfg=1,CurrentOctCfg=1,PendingMemoryInterleaveMode=1,CurrentMe
moryInterleaveMode=1;
OctantID=7,PendingOctCfg=1,CurrentOctCfg=1,PendingMemoryInterleaveMode=2,CurrentMe
moryInterleaveMode=2;
Chapter 3. Monitoring assets
189

Advertisement

Table of Contents
loading

Table of Contents