IBM Power Systems 775 Manual page 214

For aix and linux hpc solution
Table of Contents

Advertisement

Example 3-40 lsnwcomponents output example for a single 775 CEC
# lsnwcomponents
FSP Primary ip=40.10.12.1 MTMS=9125-F2C*02D7695 FR010-CG14-SN008-DR3
Example 3-41 lsnwcomponents output example for twelve 775 CEC on a single FRAME
lsnwcomponents |sort
BPA Backup ip=40.6.0.2 MTMS=78AC-100*992003H FR006
BPA Primary ip=40.6.0.1 MTMS=78AC-100*992003H FR006
FSP Backup ip=40.6.1.2 MTMS=9125-F2C*02C68B6
FSP Backup ip=40.6.10.1 MTMS=9125-F2C*02C6A46
FSP Backup ip=40.6.11.1 MTMS=9125-F2C*02C6A66
FSP Backup ip=40.6.12.1 MTMS=9125-F2C*02C6A86
FSP Backup ip=40.6.2.1 MTMS=9125-F2C*02C68D6
FSP Backup ip=40.6.3.1 MTMS=9125-F2C*02C6906
FSP Backup ip=40.6.4.1 MTMS=9125-F2C*02C6946
FSP Backup ip=40.6.5.1 MTMS=9125-F2C*02C6986
FSP Backup ip=40.6.6.1 MTMS=9125-F2C*02C69B6
FSP Backup ip=40.6.7.1 MTMS=9125-F2C*02C69D6
FSP Backup ip=40.6.8.1 MTMS=9125-F2C*02C6A06
FSP Backup ip=40.6.9.1 MTMS=9125-F2C*02C6A26
FSP Primary ip=40.6.1.1 MTMS=9125-F2C*02C68B6 FR006-CG03-SN051-DR0
FSP Primary ip=40.6.10.2 MTMS=9125-F2C*02C6A46 FR006-CG12-SN005-DR1
FSP Primary ip=40.6.11.2 MTMS=9125-F2C*02C6A66 FR006-CG13-SN005-DR2
FSP Primary ip=40.6.12.2 MTMS=9125-F2C*02C6A86 FR006-CG14-SN005-DR3
FSP Primary ip=40.6.2.2 MTMS=9125-F2C*02C68D6 FR006-CG04-SN051-DR1
FSP Primary ip=40.6.3.2 MTMS=9125-F2C*02C6906 FR006-CG05-SN051-DR2
FSP Primary ip=40.6.4.2 MTMS=9125-F2C*02C6946 FR006-CG06-SN051-DR3
FSP Primary ip=40.6.5.2 MTMS=9125-F2C*02C6986 FR006-CG07-SN004-DR0
FSP Primary ip=40.6.6.2 MTMS=9125-F2C*02C69B6 FR006-CG08-SN004-DR1
FSP Primary ip=40.6.7.2 MTMS=9125-F2C*02C69D6 FR006-CG09-SN004-DR2
FSP Primary ip=40.6.8.2 MTMS=9125-F2C*02C6A06 FR006-CG10-SN004-DR3
FSP Primary ip=40.6.9.2 MTMS=9125-F2C*02C6A26 FR006-CG11-SN005-DR0
lsnwdownhw
For this command, we list the help description that is shown in Figure 3-15. Typical output is
shown in Example 3-42 on page 201.
# lsnwdownhw -h
Usage: lsnwdownhw [ -H | --HFI | -I | --ISR | { { -L | --LINK } [ { -f <frame>
| --frame <frame> } [ -c <cage> | --cage <cage> ] | { -s <supernode> |
--supernode <supernode> } [ -d <drawer> | --drawer <drawer> ] ] } ] [ -a ] [ -p
| --page ] [ -h | --help ]
The options can be given either with '-' or '--'.
Figure 3-15 lsnwdownhw command flag description
The lsnwdownhw command lists faulty hardware in the network as, D and L links, HFIs, and
ISRs. The input and output values are:
Command: lsnwdownhw
200
IBM Power Systems 775 for AIX and Linux HPC Solution