IBM Power Systems 775 Manual page 250

For aix and linux hpc solution
Table of Contents

Advertisement

The following input and output values are used:
Command: lsdef
Flags:
– -v: Displays xCAT version information
– -d: Displays xCAT database configuration
– -a: Same as -v and -d together
Outputs:
[-v]
Version <X.Y.Z> (svn <build>, built <date>)
[-d]
cfgloc=[DB2]:<xcat_user>|<xcat_password>
dbengine=[DB2]
dbinstance=<database_instance>
dbname=<database_name>
dbloc=<database_path>
Designations: cfgloc: xCAT configuration type, user authorized to change it, and its
password.
Attributes:
– <X.Y.Z>: Version of xCAT
– <built>: SVN build number
– <date>: Build date
– <xcat_user>: Configuration user
– <xcat_password>: Configuration user password
– <database_instance>: Database instance name
– <database_name>: Database name
– <database_path>: Database path
Example 3-62 lsdef output example from "site" table
# lsdef -t site -l
Object name: clustersite
SNsyncfiledir=/var/xcat/syncfiles
blademaxp=64
cleanupxcatpost=no
consoleondemand=yes
databaseloc=/db2database
db2installloc=/mntdb2
dhcpinterfaces=en2
dnshandler=ddns
domain=ppd.pok.ibm.com
enableASMI=no
fsptimeout=0
installdir=/install
master=192.168.0.103
maxssh=8
nameservers=192.168.0.103
ntpservers=192.168.0.103
ppcmaxp=64
ppcretry=3
ppctimeout=0
sharedtftp=1
sshbetweennodes=ALLGROUPS
teal_ll_ckpt=0
236
IBM Power Systems 775 for AIX and Linux HPC Solution

Advertisement

Table of Contents
loading

Table of Contents