Solar Module Sensor 10 - Viessmann VITOTRONIC 200 Service Instructions Manual

Heat pump control unit
Table of Contents

Advertisement

Message overview
(cont.)

91 Solar module sensor 10

No switching of the appliance connected at plug
the solar control module, type SM1 (circulation pump
or 3-way diverter valve)
Cause
Short circuit, temperature sensor
module, type SM1
94 Cylinder sensor solar
No solar DHW heating with solar control module,
type SM1
Cause
Short circuit, cylinder temperature sensor at solar con-
trol module, type SM1
98 Solar module sensor 7
No control of the appliance (circulation pump or 3-way
diverter valve) connected to plug
trol module, type SM1
Cause
Short circuit, temperature sensor
module, type SM1
99 Solar module sensor 10
No switching of the appliance connected at plug
the solar control module, type SM1 (circulation pump
or 3-way diverter valve)
Cause
Lead break, temperature sensor
module, type SM1
9A Collector temp. sensor
No solar DHW heating with solar control module, type
SM1
Cause
Lead break, collector temperature sensor, solar control
module, type SM1
of
sS
Action
at solar control
Check sensor
See installation and service instructions for solar control
module, type SM1.
Action
Check sensor
See installation and service instructions for solar control
module, type SM1.
on the solar con-
sS
Action
at solar control
Check sensor
/
See installation and service instructions for solar control
module, type SM1.
of
sS
Action
at solar control
Check sensor
See installation and service instructions for solar control
module, type SM1.
Measure
Check sensor
See installation and service instructions for "Solar con-
trol module, type SM1".
Troubleshooting
on solar control module, type SM1:
%
on solar control module, type SM1:
on solar control module, type SM1:
/
on solar control module, type SM1:
&
on solar control module, type SM1:
89

Hide quick links:

Advertisement

Table of Contents
loading