Sign In
Upload
Manuals
Brands
Viessmann Manuals
Heat Pump
VITOCAL 150-A
Viessmann VITOCAL 150-A Manuals
Manuals and User Guides for Viessmann VITOCAL 150-A. We have
3
Viessmann VITOCAL 150-A manuals available for free PDF download: Service Instructions Manual, Installation And Service Instructions Manual, Operating Instructions For The System User
Viessmann VITOCAL 150-A Service Instructions Manual (200 pages)
One Base
Brand:
Viessmann
| Category:
Heat Pump
| Size: 4 MB
Table of Contents
Safety Instructions
2
Target Group
2
Working on the System
4
Connecting Cables
6
Repair Work
6
Table of Contents
9
Information Symbols
21
Introduction Scope of Functions
22
System Examples
22
Function Description CAN Bus System
23
CAN Bus Subscriber
23
Commissioning the CAN Bus Subscribers in a System Network
24
Defrost
24
Defrost Conditions
25
Defrosting Is Being Prepared
25
Defrost Process
27
End of the Defrost Process
28
Heating/Cooling
29
System Configuration
29
Determining the Flow Temperature with Weather Compensation
30
Control of the Flow Temperature for Indoor Units with 1 Integral Heating/Cooling Circuit
31
Control of the Flow Temperature for Indoor Units with 2 Integral Heating/Cooling Circuits
31
4/3-Way Valve Position for Heating/Cooling Demand
32
Starting and Stopping the Compressor When Heating/Cooling Is Required
36
Changeover Heating/Cooling
37
Auxiliary Functions
38
DHW Heating
39
Systems with DHW Cylinder
39
Flow Rate Control with Hydro Autocontrol
43
4/3-Way Valve
44
Minimum Flow Rates
45
Adjusting Minimum Flow Rates to the System Hydraulics
46
Float Air Vent Valve
47
Design
47
Separation of Refrigerant from the Heating Water
47
Further Components of the Safety Concept
48
Filling and Venting the System
49
Emergency Mode
49
Booster Heaters for Emergency Mode
50
System Configuration Setting Parameters
51
Setting Parameters on the HMI Programming Unit
51
Setting Parameters Via the Viguide App
51
Setting Parameters Via Viguide Web Applications
52
Commissioning Assistant 933 Type of Heating/Cooling Circuit 1
54
Parameter Group 933.0 Properties, Heating/Cooling Circuit 1
54
Type of Heating/Cooling Circuit 2
54
Properties, Heating/Cooling Circuit 2
54
Type of Heating/Cooling Circuit 3
54
Properties, Heating/Cooling Circuit 3
54
Type of Heating/Cooling Circuit 4
54
Properties, Heating/Cooling Circuit 4
54
1415 Operating Mode of Heating/Cooling Circuit 1
54
1416 Operating Mode of Heating/Cooling Circuit 2
55
1417 Operating Mode of Heating/Cooling Circuit 3
55
1418 Operating Mode of Heating/Cooling Circuit 4
55
General Parameter Group
59
Automatic Summer/Wintertime Changeover
60
504.6 Efficient Upper Limit
64
534.0 Circulation Pump Run-On after Cylinder Heating
64
873 DHW Hygiene Function
64
873.0 Activation of Increased DHW Hygiene
64
874 Hygiene Function for Set Cylinder Temperature
65
874.0 Set Cylinder Temperature for Increased DHW Hygiene Function
65
Holding Time, Set Cylinder Temperature for Increased DHW Hygiene Function
65
875 Hygiene Function Start Time
65
875.0 Start Time Increased DHW Hygiene
65
876 Hygiene Function Weekday
65
876.0 Weekday Increased DHW Hygiene
65
1085 Hysteresis for Cylinder Heating
66
1085.0 Start Hysteresis, Set Cylinder Temperature
66
1085.1 Stop Hysteresis, Set Cylinder Temperature
66
1087 Times for DHW Heating
66
1087.0 Max. Duration, DHW Heating
66
1087.1 Min. Delay until Next Time DHW Is Heated
66
1101 Speed Settings of the Secondary Pump for DHW Heating
67
1101.0 Secondary Pump Min. Speed for DHW Heating
67
1101.1 Secondary Pump Max. Speed for DHW Heating
67
1101.2 Secondary Pump Set Speed for DHW Heating
67
2257 Offset for Cylinder Heating
67
2257.0 Flow Temperature Boost During Cylinder Heating with Target Temperature
67
3029 Operating Mode for DHW Heating
67
3066 High DHW Demand Recognised
68
3066.0 Draw-Off Volume Threshold
68
3066.1 Time Threshold
68
3068 Set DHW Temperature for Target Temperature Control
68
3069 DHW Demand Sensor
69
Parameter Group for Heat-Notes
70
Ing/Cooling Circuit 897 Screed Drying
70
897.0 Screed Drying
70
Properties, Heating/Cooling Circuit 1
71
Priority DHW Heating, Heating/Cooling Circuit 1
71
Temperature Differential, Flow Temperature, Heating/Cooling Cir- Cuit 1
71
Room Temperature Influence, Heating, Heating/Cooling Circuit 1
71
Room Temperature Influence, Heating/Cooling Circuit 1
71
Properties, Heating/Cooling Circuit 2
71
Priority DHW Heating, Heating/Cooling Circuit 2
71
Temperature Differential, Flow Temperature, Heating/Cooling Cir- Cuit 2
72
Room Temperature Influence, Heating, Heating/Cooling Circuit 2
72
Room Temperature Influence, Heating/Cooling Circuit 2
72
Properties, Heating/Cooling Circuit 3
72
Priority DHW Heating, Heating/Cooling Circuit 3
72
Temperature Differential, Flow Temperature, Heating/Cooling Cir- Cuit 3
73
Room Temperature Influence, Heating, Heating/Cooling Circuit 3
73
Room Temperature Influence, Heating/Cooling Circuit 3
73
Properties, Heating/Cooling Circuit 4
73
Priority DHW Heating, Heating/Cooling Circuit 4
73
Temperature Differential, Flow Temperature, Heating/Cooling Cir- Cuit 4
73
Room Temperature Influence, Heating, Heating/Cooling Circuit 4
73
Room Temperature Influence, Heating/Cooling Circuit 4
74
1100 Speed Settings for Secondary Pump in Heating Mode
74
1100.0 Min. Speed, Secondary Pump
74
1100.1 Max. Speed, Secondary Pump
74
1100.2 Secondary Pump Set Speed
74
1102 Speed Settings for Heating Circuit Pump, Heating/Cooling Circuit 1
74
1102.0 Heating Circuit Pump Min. Speed, Heating/Cooling Circuit 1
74
1102.1 Heating Circuit Pump Max. Speed, Heating/Cooling Circuit 1
75
1102.2 Heating Circuit Pump Set Speed, Heating/Cooling Circuit 1
75
1103 Speed Settings for Heating Circuit Pump, Heating/Cooling Circuit 2
75
1103.0 Heating Circuit Pump Min. Speed, Heating/Cooling Circuit 2
75
1103.1 Heating Circuit Pump Max. Speed, Heating/Cooling Circuit 2
75
1103.2 Heating Circuit Pump Set Speed, Heating/Cooling Circuit 2
75
1192 Set Flow Temperature Limits, Heating/Cooling Circuit 1
75
1192.0 Min. Flow Temperature, Heating, Heating/Cooling Circuit 1
75
1192.1 Max. Flow Temperature, Heating, Heating/Cooling Circuit 1
75
1193 Set Flow Temperature Limits, Heating/Cooling Circuit 2
76
1193.0 Min. Flow Temperature, Heating, Heating/Cooling Circuit 2
76
1193.1 Max. Flow Temperature, Heating, Heating/Cooling Circuit 2
76
1194 Set Flow Temperature Limits, Heating/Cooling Circuit 3
76
1194.0 Min. Flow Temperature, Heating, Heating/Cooling Circuit 3
76
1194.1 Max. Flow Temperature, Heating, Heating/Cooling Circuit 3
77
1195 Set Flow Temperature Limits, Heating/Cooling Circuit 4
77
1195.0 Min. Flow Temperature, Heating, Heating/Cooling Circuit 4
77
1195.1 Max. Flow Temperature, Heating, Heating/Cooling Circuit 4
77
1232 Configuration of General Digital Input 1
77
1232.0 Function of Digital Input 1
77
1395 Heating Limit: Economy Function, Outside Temperature, Heating/ Cooling Circuit 1
78
1395.0 Enable Summer Economy Control, Heating/Cooling Circuit 1
78
1395.1 Summer Saving Temperature Threshold, Heating/Cooling Cir- Cuit 1
78
1396 Heating Limit: Economy Function, Outside Temperature, Heating/ Cooling Circuit 2
78
1396.0 Enable Summer Economy Control, Heating/Cooling Circuit 2
78
1396.1 Summer Saving Temperature Threshold, Heating/Cooling Cir- Cuit 2
79
1397 Heating Limit: Economy Function, Outside Temperature, Heating/ Cooling Circuit 3
79
1397.0 Enable Summer Economy Control, Heating/Cooling Circuit 3
79
1397.1 Summer Saving Temperature Threshold, Heating/Cooling Cir- Cuit 3
79
1398 Heating Limit: Economy Function, Outside Temperature, Heating/ Cooling Circuit 4
79
1398.0 Enable Summer Economy Control, Heating/Cooling Circuit 4
79
1398.1 Summer Saving Temperature Threshold, Heating/Cooling Cir- Cuit 4
80
1627 External Set Temperature for Heating/Cooling Circuit 1
80
1627.0 External Circuit Fixed Target Temperature, Heating/Cooling Cir- Cuit 1
80
1628 External Set Temperature for Heating/Cooling Circuit 2
80
1628.0 External Circuit Fixed Target Temperature, Heating/Cooling Cir- Cuit 2
80
1629 External Set Temperature for Heating/Cooling Circuit 3
80
1629.0 External Circuit Fixed Target Temperature, Heating/Cooling Cir- Cuit 3
80
1630 External Set Temperature for Heating/Cooling Circuit 4
81
Service Messages
185
Status Messages
185
Information Messages
188
CAN Bus Cable
192
Pressure Sensors
197
Advertisement
Viessmann VITOCAL 150-A Installation And Service Instructions Manual (180 pages)
Brand:
Viessmann
| Category:
Heat Pump
| Size: 25 MB
Table of Contents
Table of Contents
71
Compiling Reports
72
Switching on the Power Supply
72
Starting the Heat Pump
72
Commissioning the System
72
Filling the System
77
Building up the System Pressure
80
Venting the System
81
Opening the Heat Pump
81
Checking the Expansion Vessel and System Pressure
86
Checking All Connections on the Heating Water and DHW Sides for Leaks
86
Releasing the Outdoor Unit Transport Bracket
86
Testing the Refrigerant Circuit
87
Cleaning the Filter in the Ball Valve
89
Checking that the Fan in the Outdoor Unit Can Run Freely
89
Cleaning the Outdoor Unit Heat Exchanger (Evaporator)
90
Cleaning the Condensate Pan and Condensate Drain
91
Checking the Indoor Unit Electrical Connections for Firm Seating
92
Checking the Outdoor Unit Electrical Connections for Firm Seating
93
Resetting the High Limit Safety Cut-Out
93
Closing the Heat Pump
93
Checking the Heat Pump for Noise
95
Adjusting the Heating Curve
96
Naming the Heating/Cooling Circuits
96
Entering the Contractor's Contact Details
96
Instructing the System User
96
Viessmann VITOCAL 150-A Operating Instructions For The System User (60 pages)
Heat pump control unit with 7" touch display
Brand:
Viessmann
| Category:
Control Unit
| Size: 4 MB
Table of Contents
Table of Contents
6
Index Index
8
Safety and Liability Safety Zone
9
Liability
10
Introductory Information Symbols
11
Intended Use
11
Product Information
12
Type Plate
12
Heat Pump Control Unit
12
Permissible Ambient Temperatures in the Installation Room
13
Outside Temperature Limits
13
Safety Zone
13
Service Link
13
Low Power Radio
13
Licence Information
13
Commissioning
14
Your System Is Preset at the Factory
14
Energy Saving Tips
14
Tips for Greater Comfort
15
Quieter Operation
15
Operation Operating Principles
16
Touchscreen
16
Status Display with Lightguide
16
Screen Displays
16
Standby Display
16
Default Displays
16
Home Screen
16
Buttons and Symbols
17
Buttons and Symbols in Menu Bar a
17
Buttons and Symbols in Function Area B
17
Buttons and Symbols in Navigation Area C
18
Overview of the "Main Menu
18
Menus Available in the "Main Menu
18
Operating Program
19
Operating Programs for Room Heating, Room Cooling and DHW Heating
19
Special Operating Programs and Functions
19
Procedure for Setting a Time Program
19
Time Programs and Time Phases
20
Setting Time Phases
20
Copying the Time Program to Other Days of the Week
21
Changing Time Phases
21
Deleting Time Phases
21
Default Displays Default Display "Indoor Environment
22
DHW" Default Display
22
Energy Cockpit" Default Display
22
Checking the Heat Pump Operating Data
23
Calling up the Energy Balance
23
Favourites" Default Display
23
System Overview" Default Display
24
Room Heating/Room Cool-Selecting a Heating/Cooling Circuit
25
Ing Setting the Room Temperature for a Heating/Cooling Circuit
25
Setting Temperature Levels for Room Heating/Room Cooling
25
Switching Room Heating/Room Cooling on or off (Operating Program)
25
Time Program Room Heating/Room Cooling
26
Setting the Time Program
26
Setting the Heating Curve
26
Temporarily Adjusting the Room Temperature
27
Switching on "Extend Time Phase Once
27
Switching off "Extend Time Phase Once
27
Adjusting the Room Temperature for Longer Periods at Home
28
Switching on "Holidays at Home
28
Switching off "Holidays at Home
28
Saving Energy During Long Periods of Absence
28
Switching on the "Holiday Program
29
Switching off the "Holiday Program
29
DHW Heating DHW Temperature
30
Switching DHW Heating On/Off (Operating Program)
30
Time Program for DHW Heating
30
Setting a Time Program
30
Setting the Time Program for the DHW Circulation Pump
30
One-Off DHW Heating" Outside the Time Program
31
Switching on "One-Off DHW Heating
31
Switching off "One-Off DHW Heating
31
Increased DHW Hygiene
31
Switching on Increased DHW Hygiene
31
Switching off Increased DHW Hygiene
32
Switching DHW Scald Protection On/Off
32
Advanced Quieter Operation
33
Setting the Time Program for Quieter Operation
33
Operating Status for Quieter Operation
33
Switching Emergency Mode On/Off
33
Further Adjustments Disabling Operation
34
Unlocking the Controls
34
Changing the Password for the "Lock Panel" Function
34
Setting the Display Brightness
34
Switching the Lightguide on and off
35
Adjusting the Signal Tone for On-Screen Buttons
35
Naming Heating/Cooling Circuits
35
Setting the "Time" and "Date
36
Automatic "Summer/Wintertime" Changeover
36
Setting the "Language
36
Setting "Units
36
Entering the Contractor's Contact Details
36
Setting the Home Screen
37
Switching Internet Access on or off
37
Switching Wifi On/Off
37
Establishing a Wifi Connection
37
Static IP Addressing
38
Switching off the Display Screen for Cleaning
38
Restoring Factory Settings
38
Checks Calling up Help Messages
40
Checking Information
40
Calling up Licence Information for the Programming Unit
40
Calling up Licence Information for the Integral Communication Module TCU201
40
Calling up the License Information for Third Party Components
41
Third Party Software
41
Calling up Licence Information for the Integral Communication Module TCU300
42
Calling up the Heat Pump IP Address
42
Screed Drying
42
Checking Service Messages
42
Calling up a Service Message
43
Checking Fault Messages
43
Calling up a Fault Message
43
Checking Message Lists
44
Switching on and off Shutting down the Heat Pump
45
With Frost Protection
45
Without Frost Protection Monitoring (Shutting down the System)
45
Starting the Heat Pump
45
Position of the ON/OFF Switch
45
Wall Mounted Indoor Unit
45
Floorstanding Indoor Unit with Integral DHW Cylinder
46
What to Do if
48
Rooms Are too Cold
48
Rooms Are too Hot
48
There Is no Hot Water
49
The DHW Is too Hot
49
Warning" Is Displayed
49
Fault" Is Displayed
49
External Hook-Up" Is Displayed
49
Ë and "Service" Are Displayed
50
Panel Locked" Is Displayed
50
Maintenance Cleaning
51
Inspection and Maintenance
51
DHW Cylinder
51
Safety Valve (DHW Cylinder)
51
Potable Water Filter (if Installed)
52
Damaged Cables / Lines
52
Appendix Overview of "Main Menu
53
Information on Disposal
56
Disposal of Packaging
56
Final Decommissioning and Disposal of the Heating System
56
Keyword Index
57
Advertisement
Advertisement
Related Products
Viessmann AWOT-M-E-AC 151.A SP
Viessmann Vitocal 100-A Series
Viessmann AWO-M-AC 101.A10
Viessmann AWS-AC 110
Viessmann 18AAK
Viessmann 12AAK
Viessmann 12AAJ
Viessmann AWS-AC 113
Viessmann AWS-AC 107
Viessmann AWS-AC 104
Viessmann Categories
Boiler
Toy
Control Unit
Heat Pump
Solar panel
More Viessmann Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL