Viessmann VITOTRONIC 200 Service Instructions Manual page 157

Heat pump control unit
Table of Contents

Advertisement

Refrigerant circuit
(cont.)
Message
Meaning
code
81
Torque of compressor
H
drive too high
82
Mains voltage too high
H
(> 420 V~) or intermediate
circuit voltage too high
83
Mains voltage too low
H
(< 380 V~) or intermediate
circuit voltage too low
84
Temperature at inverter
H
(IGBT) too high
85
Temperature at inverter
H
(IGBT) too low
86
Inverter power consump-
H
tion (IGBT) permanently
too high
87
Temperature at the com-
H
pressor drive windings too
high (> 90 °C)
88
Compressor drive blocked
S
for more than 5 s.
89
A-D converter fault
S
Instrument transformer
faulty
8C
H
Modbus communication
error
8F
Inverter switched off
S
92
Compressor does not
H
reach its set speed.
Heat pump characteris-
tics
Compressor OFF
Compressor OFF
Compressor OFF
Compressor OFF
Compressor OFF
Compressor OFF
Compressor OFF
Compressor OFF
Compressor OFF
Compressor OFF
Compressor OFF
Compressor OFF
Measure
Test coil resistance at compressor. Re-
sistance on all windings must be simi-
lar (
10 %). For m
use a suitable
±
Ω
measuring device.
Test mains voltage at mains terminals:
If mains voltage is too high (+10 %),
clarify the cause in consultation with
the power supply utility.
Test mains voltage at mains terminals:
If mains voltage is too low (
clarify the cause in consultation with
the power supply utility.
Check fan at inverter heat sink. Re-
place inverter if necessary.
Replace inverter.
Test coil resistance at compressor. Re-
sistance on all windings must be simi-
lar (
10 %). For m
use a suitable
±
Ω
measuring device.
No action required
If problem recurs: Notify a specialist.
Test coil resistance at compressor.
Resistance on all windings must be
similar (
10 %). For m
±
Ω
ble measuring device.
Replace compressor and/or inverter
if necessary.
Replace inverter.
Check Modbus connecting cable, in-
verter
EEV PCB.
Check that the correct coding card is
fitted: See "System information".
Check phase sequence on compres-
sor.
Diagnosis
10 %),
use a suita-
157