Refrigerant circuit
(cont.)
Message
Meaning
code
2E
Min. required high pres-
H
sure undershot
33
Central heating/DHW
H
heating:
Secondary circuit flow
temperature too low
3A
Safety high pressure
S
switch has responded.
43
Short circuit/lead break,
S
secondary circuit flow
temperature sensor
(downstream of instanta-
neous heating water heat-
er)
44
Short circuit/lead break,
S
secondary circuit flow
temperature sensor (up-
stream of instantaneous
heating water heater)
48
Suction gas superheating
too low
49
Evaporator max. operating
pressure (MOP) has been
reached; changeover from
superheating to pressure
control of the suction gas.
4A
Evaporation temperature
too low
4C
Suction gas superheating
too high
54
Min. flow temperature pri-
H
mary circuit (brine inlet)
not achieved.
Heat pump characteris-
tics
Compressor OFF
Compressor remains in op-
eration, but does not re-
start.
Compressor OFF
Compressor OFF
Compressor OFF
Compressor OFF
Compressor remains in op-
eration.
Compressor remains in op-
eration.
Compressor OFF
Compressor OFF
Measure
Check high pressure sensor: See
message code "05".
Check amount of refrigerant. Adjust
amount if required.
Check hydraulics in the secondary
circuit, e.g. whether all shut-off
valves are fully open.
Check secondary circuit flow rate.
Check flow and return temperature
in the secondary circuit.
Check flow and return temperature
sensor in the secondary circuit.
Check amount of refrigerant. Adjust
the amount of refrigerant if necessa-
ry.
Check temperature sensors in the
refrigerant circuit.
As for "C9 Refrigerant circ (SHD)":
See "Message overview" for the heat
pump control unit.
Check resistance value (NTC 10 k
at connection J21 (T2) of the EEV
PCB: See "EEV PCB [4-6] / [4-7]".
Check resistance value (NTC 10 k
at connection J21 (T1) of the EEV
PCB: See "EEV PCB [4-6] / [4-7]".
Check whether the correct coding
card is fitted. To check information,
see "System information".
In the event of recurrence: Have the
refrigerant circuit checked by a re-
frigeration engineer.
No action required
Check primary pump.
Check whether the correct coding
card is fitted. To check information,
see "System information".
In the event of recurrence: Have the
refrigerant circuit checked by a re-
frigeration engineer.
Check primary circuit flow rate.
Diagnosis
)
Ω
)
Ω
167