Rigol MSO1000Z Series Programming Manual page 76

Digital oscilloscope
Hide thumbs Also See for MSO1000Z Series:
Table of Contents

Advertisement

RIGOL
:DECoder<n>:PARallel:NRTime
Syntax
:DECoder<n>:PARallel:NRTime <time>
:DECoder<n>:PARallel:NRTime?
Description
Set or query the noise rejection time of parallel decoding. The default unit is s.
Parameter
Name
<n>
<time>
Explanation
Before sending this command, send the
turn on the noise rejection function.
Return
The query returns the noise rejection time in scientific notation.
Format
Example
:DECoder1:PARallel:NRTime 0.01
:DECoder1:PARallel:NRTime?
:DECoder<n>:PARallel:CCOMpensation
Syntax
:DECoder<n>:PARallel:CCOMpensation <comp>
:DECoder<n>:PARallel:CCOMpensation?
Description
Set or query the clock compensation time of parallel decoding. The default unit is s.
Parameter
Name
<n>
<comp>
Explanation
Setting the compensation time can make fine adjustment of the pahse deviation
between the clock line and data line.
This command is invalid when the CLK channel source is set to OFF
(:DECoder<n>:PARallel:CLK).
Return
The query returns the compensation time in scientific notation.
Format
Example
:DECoder1:PARallel:CCOMpensation 0.01
:DECoder1:PARallel:CCOMpensation?
2-60
Type
Range
Discrete
{1|2}
Real
0.00s to 100ms
Type
Range
Discrete
{1|2}
Real
-100ms to 100ms
:DECoder<n>:PARallel:NREJect
/*Set the noise rejection time to 10ms*/
/*The query returns 1.000000e-02*/
/*Set the compensation time to 10ms*/
/*The query returns 1.000000e-02*/
MSO1000Z/DS1000Z Programming Guide
Chapter 2 Command System
Default
--
0.00s
command to
Default
--
0.00s

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents