RIGOL
:TRIGger:SPI:SLEVel
Syntax
:TRIGger:SPI:SLEVel <level>
:TRIGger:SPI:SLEVel?
Description
Set or query the trigger level of the CS channel in SPI trigger. The unit is the same as the
current amplitude unit.
Parameter
Name
<level>
Explanation
For VerticalScale, refer to :CHANnel<n>:SCALe. For OFFSet, refer
to :CHANnel<n>:OFFSet.
This command is only available when the signal source of the CS line is an analog
channel.
Return
The query returns the trigger level of the CS channel in scientific notation.
Format
Example
:TRIGger:SPI:SLEVel 0.16
:TRIGger:SPI:SLEVel?
:TRIGger:SPI:MODE
Syntax
:TRIGger:SPI:MODE <mode>
:TRIGger:SPI:MODE?
Description
Set or query the CS mode when the trigger condition is CS in SPI trigger.
Parameter
Name
<mode>
Return
The query returns HIGH or LOW.
Format
Example
:TRIGger:SPI:MODE LOW
:TRIGger:SPI:MODE?
Related
:TRIGger:SPI:WHEN
Command
2-214
Type
Range
(-5 x VerticalScale - OFFSet) to
Real
(5 x VerticalScale - OFFSet)
/*Set the trigger level of the CS channel to 160mV*/
/*The query returns 1.600000e-01*/
Type
Range
Discrete
{HIGH|LOW}
/*Set the CS mode to low*/
/*The query returns LOW*/
Chapter 2 Command System
MSO1000Z/DS1000Z Programming Guide
Default
0
Default
LOW